A parametric model of the relationship between EIT and total lung volume.

Nicolas Coulombe1, Hervé Gagnon, François Marquis, Yoanna Skrobik, Robert Guardo.   

Abstract

Spirometry and electrical impedance tomography (EIT) data from 26 healthy subjects (14 males, 12 females) were used to develop a model linking contrast variations in EIT difference images to lung volume changes. Eight recordings, each 64 s long, were made for each subject in four postures (standing, sitting, reclining at 45 degrees, supine) and two breathing modes (quiet tidal and deep breathing). Age, gender and five anthropometric variables were recorded. The database was divided into four subsets. The first subset, data from 22 subjects (12 males, 10 females) recorded in deep breathing mode, was used to create the model. Validation was done with the other subsets: data recorded during quiet tidal breathing in the same 22 subjects, and data recorded in both breathing modes for the other four subjects. A quadratic equation in DeltaV(P) (lung volume changes recorded by the spirometer) provided a very good fit to total contrast changes in the EIT images. The model coefficients were found to depend on posture, gender, thoracic circumference and scapular skin fold. To validate the model, the quadratic equation was inverted to estimate lung volume changes from the EIT images. The estimated changes were then compared to the measured volume changes. Validations with each data subset yielded mean standard errors ranging from 9.3% to 12.4%. The proposed model is a first step in enabling inter individual comparisons of EIT images since: (1) it provides a framework for incorporating the effects of anthropometric variables, gender and posture, and (2) it references the images to a physical quantity (volume) verifiable by spirometry.

Mesh:

Year:  2005        PMID: 15886435     DOI: 10.1088/0967-3334/26/4/006

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  3 in total

1.  Evaluation of surrogate measures of pulmonary function derived from electrical impedance tomography data in children with cystic fibrosis.

Authors:  Peter A Muller; Jennifer L Mueller; Michelle Mellenthin; Rashmi Murthy; Michael Capps; Brandie D Wagner; Melody Alsaker; Robin Deterding; Scott D Sagel; Jordana Hoppe
Journal:  Physiol Meas       Date:  2018-04-26       Impact factor: 2.833

2.  Chest electrical impedance tomography examination, data analysis, terminology, clinical use and recommendations: consensus statement of the TRanslational EIT developmeNt stuDy group.

Authors:  Inéz Frerichs; Marcelo B P Amato; Anton H van Kaam; David G Tingay; Zhanqi Zhao; Bartłomiej Grychtol; Marc Bodenstein; Hervé Gagnon; Stephan H Böhm; Eckhard Teschner; Ola Stenqvist; Tommaso Mauri; Vinicius Torsani; Luigi Camporota; Andreas Schibler; Gerhard K Wolf; Diederik Gommers; Steffen Leonhardt; Andy Adler
Journal:  Thorax       Date:  2016-09-05       Impact factor: 9.139

3.  Low Power Contactless Bioimpedance Sensor for Monitoring Breathing Activity.

Authors:  Marko Pavlin; Franc Novak; Gregor Papa
Journal:  Sensors (Basel)       Date:  2021-03-16       Impact factor: 3.576