Literature DB >> 15885788

The effect of periocular warming on accommodation.

Yoko Takahashi1, Michihito Igaki, Atsushi Suzuki, Genichiro Takahashi, Murat Dogru, Kazuo Tsubota.   

Abstract

PURPOSE: To investigate the effect of periocular warming on accommodation amplitude and near vision after prolonged near work in visual display terminal (VDT) workers in an office setting.
DESIGN: Prospective interventional observational case series. PARTICIPANTS: Ten healthy Japanese male volunteers (mean age, 39.3+/-2 years [range, 36-43]) with a best distance corrected visual acuity (VA) of >20/20 who performed near work for 7 hours were included in the study. MAIN OUTCOME MEASURES: The differences of subjective and objective accommodations, near acuity, and pupil diameters were compared and studied in 2 experimental settings with and without periocular warming.
METHODS: Two experiments were performed on each subject on 2 different days. In one experiment, the subjects wore an eye mask and closed their eyelids for 10 minutes after 7 hours of VDT work (lid closure [LC] group). In the other experiment, the subjects applied warming sheets (WSs) to their eyelids and the periocular region and wore masks for 10 minutes again after 7 hours of VDT work (WS group). Visual display terminal work was performed under the same settings on both days. Subjective and objective accommodations, near vision, and pupil diameters were measured immediately before and immediately after the resting or warming procedure and again 90 minutes after the resting or warming procedures.
RESULTS: Fifty percent of eyes had an increase in the accommodation amplitude of at least 0.5 diopters immediately after application of the WSs. Forty percent of eyes still maintained the accommodation amplitude level at 90 minutes. The mean near logarithm of the minimum angle of resolution VA immediately after application of WSs and at 90 minutes significantly improved relative to the near acuity values after simple eyelid closure.
CONCLUSION: Periocular warming was found to be associated with increases in subjective and objective accommodations, with a concomitant improvement in near VA. Periocular warming with disposable WSs is a simple and effective method of increasing near work-related ergonomy.

Entities:  

Mesh:

Year:  2005        PMID: 15885788     DOI: 10.1016/j.ophtha.2004.12.040

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  6 in total

Review 1.  Thresholds for thermal damage to normal tissues: an update.

Authors:  Pavel S Yarmolenko; Eui Jung Moon; Chelsea Landon; Ashley Manzoor; Daryl W Hochman; Benjamin L Viglianti; Mark W Dewhirst
Journal:  Int J Hyperthermia       Date:  2011       Impact factor: 3.914

2.  Living with presbyopia: experiences from a virtual roundtable dialogue among impacted individuals and healthcare professionals.

Authors:  Mile Brujic; Paola Kruger; Jeff Todd; Elizabeth Barnes; Mark Wuttke; Flavia Perna; Jorge Aliò
Journal:  BMC Ophthalmol       Date:  2022-05-05       Impact factor: 2.086

3.  The Effects of Chewing Gum in Preventing Eyestrain.

Authors:  Ken Asakawa; Susumu Kanno; Tomonori Ando; Kenji Osawa; Hitoshi Ishikawa
Journal:  Biomed Res Int       Date:  2020-11-12       Impact factor: 3.411

4.  Oral administration of resveratrol or lactic acid bacterium improves lens elasticity.

Authors:  Hayato Nagashima; Nobunari Sasaki; Sachie Amano; Shigeru Nakamura; Motoshi Hayano; Kazuo Tsubota
Journal:  Sci Rep       Date:  2021-01-26       Impact factor: 4.379

Review 5.  Let There Be Light-Digital Eye Strain (DES) in Children as a Shadow Pandemic in the Era of COVID-19: A Mini Review.

Authors:  Sudip Bhattacharya; Petra Heidler; Sheikh Mohd Saleem; Roy Rillera Marzo
Journal:  Front Public Health       Date:  2022-08-11

6.  Warming device for computer vision syndrome.

Authors:  K Ilango
Journal:  Indian J Ophthalmol       Date:  2008 Mar-Apr       Impact factor: 1.848