Literature DB >> 15881467

Sampling and determination of volatile organic compounds with needle trap devices.

Aiping Wang1, Fang Fang, Janusz Pawliszyn.   

Abstract

In this study, a sorbent was immobilized inside a needle resulting in the development of a needle trap (NT) device. This device was applied to extract organic components from gaseous samples and to introduce an enriched mixture into a conventional gas chromatography (GC) injector. Construction of this simple and integrated sampling/extraction/sample introduction device was optimized by considering different ways to immobilize a sorbent in the needle, packing single and multiple-layer sorbent beds, and applying different desorption strategies into the GC injector. A carrier gas system was modified to minimize the carryover for the needle trap with a sealed tip (NT-1), and a narrow-neckliner was used for the blunt-tip needle trap (NT-2). Breakthrough in the device was investigated by connecting two NT-2 devices in series. The needle trap performed very well as an exhaustive spot sampler, as well as in a time-weighted average (TWA) operation. The linear velocity of the mobile phase has no influence on the sampling rate of the needle trap. Validation results against the standard NIOSH 1501 method using charcoal tubes for indoor air surveys demonstrated good accuracy for the NT approach. The reproducibility of the NT-2 was about 1% for benzene. The detection limits for FID detection and for 25 ml gas sample were 0.23 ng/l, 2.10 ng/l and 1.12 ng/l for benzene, ethylbenzene and o-xylene, respectively.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15881467     DOI: 10.1016/j.chroma.2004.12.064

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  5 in total

1.  Analysis of formaldehyde and acrolein in the aqueous samples using a novel needle trap device containing nanoporous silica aerogel sorbent.

Authors:  Abdullah Barkhordari; Mansour R Azari; Rezvan Zendehdel; Mahmoud Heidari
Journal:  Environ Monit Assess       Date:  2017-03-20       Impact factor: 2.513

2.  Gas chromatographic determination of volatile compounds.

Authors:  Ikuo Ueta
Journal:  Anal Sci       Date:  2022-05       Impact factor: 2.081

3.  Application of a needle trap device packed with a MIP@MOF nano-composite for efficient sampling and determination of airborne diazinon pesticide.

Authors:  Razzagh Rahimpoor; Ali Firoozichahak; Saber Alizadeh; Danial Soleymani-Ghoozhdi; Faeze Mehregan
Journal:  RSC Adv       Date:  2022-05-31       Impact factor: 4.036

4.  Risk assessment of occupational exposure to benzene using numerical simulation in a complex geometry of a reforming unit of petroleum refinery.

Authors:  Majid Bayatian; Khosro Ashrafi; Mansour Rezazadeh Azari; Mohammad Javad Jafari; Yadollah Mehrabi
Journal:  Environ Sci Pollut Res Int       Date:  2018-02-07       Impact factor: 4.223

5.  Optimization strategies of in-tube extraction (ITEX) methods.

Authors:  Jens Laaks; Maik A Jochmann; Beat Schilling; Torsten C Schmidt
Journal:  Anal Bioanal Chem       Date:  2015-06-30       Impact factor: 4.142

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.