Literature DB >> 15878783

Electrochemical impedance spectroscopy study of Ti-6Al-4V alloy in artificial saliva with fluoride and/or bovine albumin.

Her-Hsiung Huang1, Tzu-Hsin Lee.   

Abstract

OBJECTIVES: To investigate the electrochemical mechanism of Ti-6Al-4V alloy in acidic artificial saliva with NaF and/or bovine albumin (BA).
METHODS: The electrochemical behavior of Ti-6Al-4V alloy was investigated using electrochemical impedance spectroscopy (EIS) measurements at the open circuit potentials. The electrolytes used included artificial saliva with 0-0.5% NaF, with 0.1% NaF+0.01-0.5% BA, and with 0.01-0.5% BA at pH 5 and 37 degrees C. One-way ANOVA was used to analyze the influence of NaF and BA concentration on the polarization resistance (Rp) obtained from the EIS data. Surface chemical analyses were performed with X-ray photoelectron spectroscopy.
RESULTS: The impedance was mainly characterized by the resistance and capacitance of a protective TiO2-based passive film on Ti-6Al-4V alloy when NaF concentration was low (< or = 0.01%). When NaF concentration was higher than 0.1%, the impedance was characterized by two capacitive and one inductive effects, which were related to the metal's charge transfer reaction and the decayed TiO2-based oxide film (capacitive effects), and the relaxation of the adsorbed Ti-F complex compound (inductive effect). The addition of 0.01-0.5% BA in 0.1% NaF-containing artificial saliva significantly increased the impedance of Ti-6Al-4V alloy compared to that without BA addition (p < 0.001). The presence of BA in fluoride-free artificial saliva had no influence on the electrochemical impedance of Ti-6Al-4V alloy (p > 0.05). SIGNIFICANCE: The EIS measurement technique is suitable for the study of the electrochemical behavior of dental alloy. The electrochemical mechanism of Ti-6Al-4V alloy in artificial saliva is related to the fluoride and bovine albumin concentration.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15878783     DOI: 10.1016/j.dental.2005.01.009

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  5 in total

1.  Corrosion Performance of Fe-Cr-Ni Alloys in Artificial Saliva and Mouthwash Solution.

Authors:  J Porcayo-Calderon; M Casales-Diaz; V M Salinas-Bravo; L Martinez-Gomez
Journal:  Bioinorg Chem Appl       Date:  2015-05-06       Impact factor: 7.778

2.  Electrochemical Behaviour and Galvanic Effects of Titanium Implants Coupled to Metallic Suprastructures in Artificial Saliva.

Authors:  Ana Mellado-Valero; Anna Igual Muñoz; Virginia Guiñón Pina; Ma Fernanda Sola-Ruiz
Journal:  Materials (Basel)       Date:  2018-01-22       Impact factor: 3.623

3.  Corrosion resistance of different nickel-titanium archwires in acidic fluoride-containing artificial saliva.

Authors:  Tzu-Hsin Lee; Ta-Ko Huang; Shu-Yuan Lin; Li-Kai Chen; Ming-Yung Chou; Her-Hsiung Huang
Journal:  Angle Orthod       Date:  2010-05       Impact factor: 2.079

4.  Commercial oral hygiene products and implant collar surfaces: Scanning electron microscopy observations.

Authors:  Serena Bianchi; Giulia Fantozzi; Sara Bernardi; Sevastiani Antonouli; Maria Adelaide Continenza; Guido Macchiarelli
Journal:  Can J Dent Hyg       Date:  2020-02-01

Review 5.  A Critical Appraisal of the Use and Properties of Nickel-Titanium Dental Alloys.

Authors:  Petra Močnik; Tadeja Kosec
Journal:  Materials (Basel)       Date:  2021-12-18       Impact factor: 3.623

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.