Literature DB >> 15877983

Comparison of thrombosis and restenosis risk from stent length of sirolimus-eluting stents versus bare metal stents.

Laura Mauri1, A James O'Malley, Jeffrey J Popma, Jeffrey W Moses, Martin B Leon, David R Holmes, Paul S Teirstein, Donald E Cutlip, Dennis Donahoe, Richard E Kuntz.   

Abstract

Selection of coronary stent length varies from covering only the zone of maximum obstruction to stenting from normal- to normal-appearing vessels. With bare metal stenting, for any given lesion there is a high restenotic risk associated with longer stent length. With drug-eluting stents, the relation between stent length and restenosis has not been evaluated. In the angiographic follow-up cohort of the SIRIUS trial that compared the sirolimus-eluting Bx Velocity stent with the standard Bx Velocity stent (n = 699), we constructed a multiple regression model to predict 8-month percent diameter stenosis using the main effects of lesion length and excess stent length beyond the lesion length and adjusting for known predictors of restenosis. Stent length exceeded lesion length in 94% of lesions overall. Mean difference in length was 8.3 +/- 8.3 mm (mean lesion length 14.6 +/- 5.9 mm, mean stent length 22.9 +/- 9.6 mm). Stented lesion length and excess stent length were associated with absolute increases in percent diameter stenosis per 10 mm of 9.1% (p <0.0001) and 3.6% (p = 0.053) in the bare metal arm and 3.5% (p = 0.047) and 2.1% (p = 0.040) in the sirolimus-eluting stent arm. Although the effects of lesion length and excess stent length on restenosis were markedly decreased with sirolimus-eluting stents (vs bare metal stents), a small restenotic penalty is still paid for excessive stent length. Longer stent-to-lesion length strategies should be used only when a shorter stent is likely to result in incomplete lesion coverage and edge dissection, a strong determinant of stent thrombosis.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15877983     DOI: 10.1016/j.amjcard.2005.01.039

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  8 in total

1.  Relationship between atherogenic index of plasma and stent thrombosis in patients with acute coronary syndrome.

Authors:  Özge Özcan Abacıoğlu; Arafat Yıldırım; Nermin Yıldız Koyunsever; Mine Karadeniz; Salih Kılıç
Journal:  Anatol J Cardiol       Date:  2022-02       Impact factor: 1.596

Review 2.  Robotic-assisted angioplasty: current status and future possibilities.

Authors:  Nathaniel R Smilowitz; Giora Weisz
Journal:  Curr Cardiol Rep       Date:  2012-10       Impact factor: 2.931

Review 3.  Robotic-Assisted Percutaneous Coronary Intervention.

Authors:  Nathan Lo; Jorge Antonio Gutierrez; Rajesh V Swaminathan
Journal:  Curr Treat Options Cardiovasc Med       Date:  2018-02-24

4.  Impact of stent length and diameter on short term clinical outcomes of drug eluting stents in patients with stable coronary artery disease.

Authors:  Yasir Adnan; Lubna Noor; Muhammad Habeel Dar; Umair Ali; Muhammad Hafizullah
Journal:  Pak J Med Sci       Date:  2017 Jul-Aug       Impact factor: 1.088

5.  Endothelial Cell Distribution After Flow Exposure With Two Stent Struts Placed in Different Angles.

Authors:  Zi Wang; Narendra Kurnia Putra; Hitomi Anzai; Makoto Ohta
Journal:  Front Physiol       Date:  2022-01-13       Impact factor: 4.566

6.  Procedural Safety and Long-Term Clinical Outcomes in Patients Receiving Ultra-Long Everolimus-Eluting Stent: A Single-Center Real-World Experience.

Authors:  Nagendra Boopathy Senguttuvan; Rahul Kongara; Shanmugasundram Sadhanandham; Nishok Victory Srinivasan; Santhosh Kumar Periyasamy; Balakrishnan Vinod Kumar; Ravi Shankar P; Meena Iyer; Mahalakshmi Ramadoss; Vinodhini Subramanian; Jayanthy Venkata Balasubramaniyan; Preetam Krishnamurthy; Sankaran Ramesh; Panchanatham Manokar; Thoddi Ramamurthy Muralidharan; Jayanthi Sathyanarayana Murthy; Sadagopan Thanikachalam
Journal:  Cardiol Res       Date:  2022-04-05

7.  Lesion length impacts long term outcomes of drug-eluting stents and bare metal stents differently.

Authors:  Shang-Hung Chang; Chun-Chi Chen; Ming-Jer Hsieh; Chao-Yung Wang; Cheng-Hung Lee; I-Chang Hsieh
Journal:  PLoS One       Date:  2013-01-11       Impact factor: 3.240

8.  Safety and efficacy of Everolimus-Eluting bioabsorbable Polymer-Coated stent in patients with long coronary lesions: The EVOLVE 48 study.

Authors:  Dimitrios Karmpaliotis; Robert Stoler; Simon Walsh; Seif El-Jack; Srinivasa Potluri; Jeffrey Moses; Keith Oldroyd; Adrian Banning; Mark Webster; Azfar Zaman; Willis Wu; Mudassar Ahmed; Paul Underwood; Dominic Allocco
Journal:  Catheter Cardiovasc Interv       Date:  2021-05-29       Impact factor: 2.585

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.