Literature DB >> 15877747

Microbiological and clinical outcomes and patient satisfaction for two treatment options in the edentulous lower jaw after 10 years of function.

Marc Quirynen1, Ghada Alsaadi, Martine Pauwels, Anne Haffajee, Daniel van Steenberghe, Ignace Naert.   

Abstract

BACKGROUND: Long-term data on microbiological and clinical outcome as well as on patient satisfaction after implant therapy in the edentulous mandible are limited. Especially comparisons between fixed full prostheses (FFPs) and overdentures (ODs), or between anchoring systems for the latter are scarce. AIM: This study aimed to evaluate both of these parameters at the 10-year follow-up in a group of fully edentulous patients rehabilitated via an OD or a FFP (the latter to allow inter-group comparison).
MATERIAL AND METHODS: A total of 37 fully edentulous patients (25 ODs, 12 FFPs, age at implant installation ranged from 36 to 85 years) participated in this study. All subjects received their implants (Branemark System, Nobel Biocare AB, Gothenburg, Sweden) 10 years previously. For the ODs different attachment systems (bar, magnets, ball) had been applied that allowed a further intra-group comparison. At the follow-up visit, 10 years after the abutment insertion, a series of periodontal parameters were recorded, long-cone radiographs were taken and subgingival plaque samples were collected for analysis using checkerboard DNA-DNA hybridization. The clinical and radiographic data were recorded at abutment connection and after 1 and 10 years.
RESULTS: After 10 years of loading, mean plaque and bleeding indices and changes in attachment or marginal bone level were not significantly different, neither between the OD and FFP group, nor within the OD group. The marginal bone loss between abutment connection and year 10 was 0.86 and 0.73 mm for OD and FFP groups, respectively. The subgingival microbiota at implant sites from all (sub)-groups was comparable, with low numbers of DNA counts (+/-10 x 10(5)) but high detection frequencies of Actinobacillus actinomycetemcomitans (>90%), Porphyromonas gingivalis (>85%) and Tannerella forsythensis (30%). The composition of the subgingival microbiota was influenced by probing depth and bleeding tendency. Patient satisfaction was very high for both types of prosthetic rehabilitation. The FFP group scored only slightly better for chewing comfort and general satisfaction.
CONCLUSION: These data indicate that from the clinical and microbiological standpoint, as well as patient satisfaction, both an OD and a FFP offer a favourable long-term outcome.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15877747     DOI: 10.1111/j.1600-0501.2005.01127.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  6 in total

1.  Bacterial diversity of periodontal and implant-related sites detected by the DNA Checkerboard method.

Authors:  C do Nascimento; N Monesi; I Y Ito; J P M Issa; R F de Albuquerque Junior
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2011-04-30       Impact factor: 3.267

2.  Standardizing the evaluation criteria on treatment outcomes of mandibular implant overdentures: a systematic review.

Authors:  Ha-Young Kim; Sang-Wan Shin; Jeong-Yol Lee
Journal:  J Adv Prosthodont       Date:  2014-10-21       Impact factor: 1.904

Review 3.  Implant Supported Fixed Restorations versus Implant Supported Removable Overdentures: A Systematic Review.

Authors:  Khaled Selim; Sherif Ali; Ahmed Reda
Journal:  Open Access Maced J Med Sci       Date:  2016-10-14

4.  Microbiological evaluation of LOCATOR® Legacy attachments: A cross-sectional clinical study.

Authors:  Ursina Nagy; Christophe Guédat; Catherine Giannopoulou; Martin Schimmel; Frauke Müller; Murali Srinivasan
Journal:  Clin Exp Dent Res       Date:  2019-07-18

5.  A new implant-abutment connection for bacterial microleakage prevention: an in vitro study.

Authors:  L Tettamanti; F Cura; C Andrisani; M Andreasi Bassi; J Silvestrerangil; A Tagliabue
Journal:  Oral Implantol (Rome)       Date:  2017-09-27

6.  Osseointegrated implants placed at supracrestal level may harbour higher counts of A. gerencseriae and S. constellatus - a randomized, controlled pilot study.

Authors:  Mariana Ribeiro de Moraes Rego; Marcelo Ferreira Torres; Luiz Carlos Santiago; Ronaldo Lira-Junior; Eduardo José Veras Lourenço; Daniel de Moraes Telles; Carlos Marcelo Figueredo
Journal:  J Oral Microbiol       Date:  2015-10-23       Impact factor: 5.474

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.