| Literature DB >> 15877174 |
Abstract
Tris(chloro-isopropyl)phosphate (TCPP) was identified by GC-MS by comparing mass spectra and retention times to original standards. The concentrations in wastewater of a sewage treatment plant's influent and effluent were analysed (520 ng l(-1) and 380 ng l(-1), respectively (mean values). The concentrations of TCPP in the wastewater inflow exhibited a high variability. The elimination of this compound in the sewage treatment plant also exhibits a high variability but is low. Additionally the concentrations in sewage sludge of the same plant were determined (mean value 5100 ng g(-1) dry weight; 1700 ng g(-1) wet weight, respectively). For a comparison sludge samples from twenty other plants were analysed. In these samples concentrations ranging from 1000-20000 ng g(-1)(dry weight) were determined. Thus sorption to sludge does occur to some extent.Entities:
Mesh:
Substances:
Year: 2005 PMID: 15877174 DOI: 10.1039/b502318a
Source DB: PubMed Journal: J Environ Monit ISSN: 1464-0325