Efficiency of the ortho VITROS assay for detection of hepatitis C virus-specific antibodies increased by elimination of supplemental testing of samples with very low sample-to-cutoff ratios.

Margret Oethinger1, Donald R Mayo, JoAnne Falcone, Pankaj K Barua, Brigitte P Griffith.   

Abstract

The clinical significance of specimens with low sample-to-cutoff (S/Co) ratios in the Ortho VITROS chemiluminescence assay (CIA) for detection of antibodies to hepatitis C virus (HCV) was evaluated. In one study of 482 CIA-reactive samples, none of the 83 samples with S/Co ratios of < 5 was HCV RNA positive. In a subsequent study, 332 samples with S/Co ratios of between 1 and 20 were tested with the recombinant immunoblot assay (RIBA). None of the 163 samples with S/Co ratios of < 5 was RIBA positive, 83% were RIBA negative, and 28 samples (18%) were RIBA indeterminate. HCV RNA and/or clinical evidence of hepatitis was not found in the 27 indeterminate cases examined. These results show that over 99% of samples with very low S/Co ratios (< or = 5) have no evidence of HCV infection. Therefore, we suggest that the HCV antibody testing algorithm for the VITROS assay might be modified to eliminate supplemental testing of samples with very low S/Co ratios.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15872288      PMCID: PMC1153771          DOI: 10.1128/JCM.43.5.2477-2480.2005

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  10 in total

1.  Serodiagnosis of hepatitis C virus. Effect of new evaluation of cutoff values for enzyme-linked immunosorbent assay in Brazilian patients.

Authors:  V A dos Santos; R S Azevedo; M E Camargo; V A Alves
Journal:  Am J Clin Pathol       Date:  1999-09       Impact factor: 2.493

2.  Chemiluminescence assay improves specificity of hepatitis C antibody detection.

Authors:  D Robert Dufour; Mageli Talastas; Maria D A Fernandez; Barbara Harris
Journal:  Clin Chem       Date:  2003-06       Impact factor: 8.327

3.  Significance of NS3 and NS5 antigens in screening for HCV antibody.

Authors:  K Vernelen; H Claeys; H Verhaert; A Volckaerts; C Vermylen
Journal:  Lancet       Date:  1994-04-02       Impact factor: 79.321

4.  Lookback on donors who are repeatedly reactive on first-generation hepatitis C virus assays:justification and rational implementation.

Authors:  L H Tobler; G Tegtmeier; S L Stramer; S Quan; J Dockter; C Giachetti; M P Busch
Journal:  Transfusion       Date:  2000-01       Impact factor: 3.157

5.  Significance of indeterminate third-generation hepatitis C virus recombinant immunoblot assay.

Authors:  J M Pawlotsky; A Bastie; C Pellet; J Remire; F Darthuy; L Wolfe; C Sayada; J Duval; D Dhumeaux
Journal:  J Clin Microbiol       Date:  1996-01       Impact factor: 5.948

6.  Guidelines for laboratory testing and result reporting of antibody to hepatitis C virus. Centers for Disease Control and Prevention.

Authors:  Miriam J Alter; Wendi L Kuhnert; Lyn Finelli
Journal:  MMWR Recomm Rep       Date:  2003-02-07

7.  Low-positive anti-hepatitis C virus enzyme immunoassay results: an important predictor of low likelihood of hepatitis C infection.

Authors:  D Robert Dufour; Mageli Talastas; Maria D A Fernandez; Barbara Harris; Doris B Strader; Leonard B Seeff
Journal:  Clin Chem       Date:  2003-03       Impact factor: 8.327

8.  Anti-hepatitis C virus (anti-HCV) seroconversion in patients undergoing hemodialysis: comparison of second- and third-generation anti-HCV assays.

Authors:  A M Couroucé; N Le Marrec; A Girault; S Ducamp; N Simon
Journal:  Transfusion       Date:  1994-09       Impact factor: 3.157

9.  Laboratory evaluation of a fully automated chemiluminescence immunoassay for rapid detection of HBsAg, antibodies to HBsAg, and antibodies to hepatitis C virus.

Authors:  Nahed Ismail; Geoffrey E Fish; Michael B Smith
Journal:  J Clin Microbiol       Date:  2004-02       Impact factor: 5.948

10.  Reliability of the third-generation recombinant immunoblot assay for hepatitis C virus.

Authors:  M Damen; H L Zaaijer; H T Cuypers; H Vrielink; C L van der Poel; H W Reesink; P N Lelie
Journal:  Transfusion       Date:  1995-09       Impact factor: 3.157

  10 in total
  13 in total

1.  Discordant results of two automated assays for detection of hepatitis C virus-specific antibody.

Authors:  Irwin S Fox
Journal:  J Clin Microbiol       Date:  2006-04       Impact factor: 5.948

2.  Evaluation of the Ortho-Clinical Diagnostics Vitros ECi Anti-HCV test: comparison with three other methods.

Authors:  Jeannette M Watterson; Paulina Stallcup; David Escamilla; Patrick Chernay; Alfred Reyes; Sylvia C Trevino
Journal:  J Clin Lab Anal       Date:  2007       Impact factor: 2.352

3.  Retrospective analysis on the diagnostic performances and signal-to-cut-off ratios of the Elecsys Anti-HCV II assay.

Authors:  Banseok Kim; Hyo Jun Ahn; Min Hyuk Choi; Yongjung Park
Journal:  J Clin Lab Anal       Date:  2017-02-10       Impact factor: 2.352

4.  Comparison of serial Hepatitis C virus detection in samples submitted through serology for reflex confirmation versus samples directly submitted for quantitation.

Authors:  Howard B Gale; D Robert Dufour; Nazia N Qazi; Virginia L Kan
Journal:  J Clin Microbiol       Date:  2011-06-08       Impact factor: 5.948

5.  Role of signal-to-cutoff ratios in hepatitis C virus antibody detection.

Authors:  Marco Moretti; Barbara Pieretti; Annamaria Masucci; Davide Sisti; Marco Rocchi; Ernesto Delprete
Journal:  Clin Vaccine Immunol       Date:  2012-06-13

6.  Evaluation of Quantitative Real-Time PCR as a Hepatitis C Virus Supplementary Test After RIBA Discontinuation.

Authors:  Shunyou Gong; Christine L Schmotzer; Lan Zhou
Journal:  J Clin Lab Anal       Date:  2015-10-26       Impact factor: 2.352

7.  Determining immunoassay cutoff value using Western blot results to predict hepatitis C infection in blood donors with low-titer anti-HCV reactivity.

Authors:  Abdulkadir Kucukbayrak; Saadet Cakmak; Ismail Necati Hakyemez; Tekin Tas; Hayrettin Akdeniz
Journal:  Folia Microbiol (Praha)       Date:  2012-12-04       Impact factor: 2.099

8.  Hepatitis C virus (HCV)-specific immune responses of long-term injection drug users frequently exposed to HCV.

Authors:  Eishiro Mizukoshi; Christoph Eisenbach; Brian R Edlin; Kimberly P Newton; Sukanya Raghuraman; Christina Weiler-Normann; Leslie H Tobler; Michael P Busch; Mary Carrington; Jane A McKeating; Thomas R O'Brien; Barbara Rehermann
Journal:  J Infect Dis       Date:  2008-07-15       Impact factor: 5.226

9.  Clinical performance evaluation of four automated chemiluminescence immunoassays for hepatitis C virus antibody detection.

Authors:  Sinyoung Kim; Jeong-Ho Kim; Seoyoung Yoon; Youn-Hee Park; Hyon-Suk Kim
Journal:  J Clin Microbiol       Date:  2008-10-22       Impact factor: 5.948

10.  Anti-HCV signal-to-cutoff ratio in predicting hepatitis C viremia.

Authors:  Hyon-Suk Kim
Journal:  Korean J Intern Med       Date:  2009-11-27       Impact factor: 3.165

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.