Literature DB >> 15871919

Hand-held monitor of sympathetic nervous system using salivary amylase activity and its validation by driver fatigue assessment.

Masaki Yamaguchi1, Mitsuo Deguchi, Junichi Wakasugi, Shin Ono, Noriyasu Takai, Tomoyuki Higashi, Yasufumi Mizuno.   

Abstract

In order to realize a hand-held monitor of the sympathetic nervous system, we fabricated a completely automated analytical system for salivary amylase activity using a dry-chemistry system. This was made possible by the fabrication of a disposable test-strip equipped with built-in collecting and reagent papers and an automatic saliva transfer device. In order to cancel out the effects of variations in environmental temperature and pH of saliva, temperature- and pH-adjusted equations were experimentally determined, and each theoretical value was input into the memory of the hand-held monitor. Within a range of salivary amylase activity between 10 and 140 kU/l, the calibration curve for the hand-held monitor showed a coefficient with R(2)=0.97. Accordingly, it was demonstrated that the hand-held monitor enabled a user to automatically measure the salivary amylase activity with high accuracy with only 30 microl sample of saliva within a minute from collection to completion of the measurement. In order to make individual variations of salivary amylase activity negligible during driver fatigue assessment, a normalized equation was proposed. The normalized salivary amylase activity correlated with the mental and physical fatigue states. Thus, this study demonstrated that an excellent hand-held monitor with an algorithm for normalization of individuals' differences in salivary amylase activity, which could be easily and quickly used for evaluating the activity of the sympathetic nervous system at any time. Furthermore, it is suggested that the salivary amylase activity might be used as a better index for psychological research.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 15871919     DOI: 10.1016/j.bios.2005.03.014

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  34 in total

Review 1.  Wearable biosensors for healthcare monitoring.

Authors:  Jayoung Kim; Alan S Campbell; Berta Esteban-Fernández de Ávila; Joseph Wang
Journal:  Nat Biotechnol       Date:  2019-02-25       Impact factor: 54.908

Review 2.  A Taxonomy of Fatigue Concepts and Their Relation to Hearing Loss.

Authors:  Benjamin W Y Hornsby; Graham Naylor; Fred H Bess
Journal:  Ear Hear       Date:  2016 Jul-Aug       Impact factor: 3.570

3.  Trends in research related to "Shinrin-yoku" (taking in the forest atmosphere or forest bathing) in Japan.

Authors:  Yuko Tsunetsugu; Bum-Jin Park; Yoshifumi Miyazaki
Journal:  Environ Health Prev Med       Date:  2010-01       Impact factor: 3.674

4.  Performance Evaluation of a Salivary Amylase Biosensor for Stress Assessment in Military Field Research.

Authors:  Henry T Peng; Erin Savage; Oshin Vartanian; Shane Smith; Shawn G Rhind; Catherine Tenn; Stephen Bjamason
Journal:  J Clin Lab Anal       Date:  2015-01-19       Impact factor: 2.352

5.  Efficacy of Parietal Acupoint Therapy: Scalp Acupuncture for Neck/Shoulder Stiffness with Related Mood Disturbance.

Authors:  Naoki Aoyama; Osamu Fujii; Toshikatsu Yamamoto
Journal:  Med Acupunct       Date:  2017-12-01

Review 6.  Mobile devices for the remote acquisition of physiological and behavioral biomarkers in psychiatric clinical research.

Authors:  Zachary W Adams; Erin A McClure; Kevin M Gray; Carla Kmett Danielson; Frank A Treiber; Kenneth J Ruggiero
Journal:  J Psychiatr Res       Date:  2016-10-22       Impact factor: 4.791

7.  Salivary biosensors for screening trauma-related psychopathology.

Authors:  Vivek Shetty; Masaki Yamaguchi
Journal:  Oral Maxillofac Surg Clin North Am       Date:  2010-05       Impact factor: 2.802

8.  Monitoring salivary amylase activity is useful for providing timely analgesia under sedation.

Authors:  Masaya Uesato; Yoshihiro Nabeya; Takashi Akai; Masahito Inoue; Yoshiyuki Watanabe; Daisuke Horibe; Hiroshi Kawahira; Hideki Hayashi; Hisahiro Matsubara
Journal:  World J Gastrointest Endosc       Date:  2014-06-16

9.  The relationship of serum and salivary cortisol levels to male sexual dysfunction as measured by the International Index of Erectile Function.

Authors:  Y Kobori; E Koh; K Sugimoto; K Izumi; K Narimoto; Y Maeda; H Konaka; A Mizokami; T Matsushita; T Iwamoto; M Namiki
Journal:  Int J Impot Res       Date:  2009-05-07       Impact factor: 2.896

10.  Clinical Performance of a Salivary Amylase Activity Monitor During Hemodialysis Treatment.

Authors:  Masaru Shimazaki; Takayuki Matsuki; Kazuaki Yamauchi; Michihiro Iwata; Hiroshi Takahashi; Kenichi Sakamoto; Junichi Ohata; Yuichi Nakamura; Yusuke Okazaki
Journal:  Biomark Insights       Date:  2008-09-15
View more