Abstract

BACKGROUND: We aimed to evaluate the efficacy of a breath-hold superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance (MR) imaging protocol for the detection of focal hepatic lesions, in comparison with a non-breath-hold SPIO-enhanced imaging protocol and computed tomography during arterioportography (CTAP) plus CT during hepatic arteriography (CTHA).
METHODS: Findings of SPIO-enhanced MR imaging and CTAP/CTHA for 24 hepatic metastases in 17 patients and 29 HCCs in 21 patients were analyzed. All patients underwent breath-hold SPIO-enhanced MR imaging (1.5 tesla), breath-hold plus non-breath-hold SPIO-enhanced MR imaging, and CTAP plus CTHA prior to partial hepatectomy or laparoscopic ablation therapy. Histopathology for lesion characterization and intraoperative ultrasound for lesion detection were available for all patient. Breath-hold SPIO-enhanced MR imaging consisted of T2-weighted single-short fast spin echo (FSE), T2-weighted (T2W) FSE, T2*-weighted gradient echo (GRE), and T1-weighted GRE. For the non-breath-hold imaging protocol, respiratory-triggered, fat-suppressed T2W-FSE was added to the breath-hold MR imaging protocol. Double phase CTAP plus CTHA was performed on an angio-CT system. To compare the three imaging protocols, three radiologists performed blind film reading, and all data, on a hepatic segment-to-segment basis, were entered for alternative free-response receiver-operating characteristic (AFROC) analysis.
RESULTS: ROC analysis showed that there was no significant difference in the area under the AFROC curve (A1) value for metastases and HCCs among the three protocols; the breath-hold SPIO-enhanced MR imaging protocol, non-breath-hold MR imaging protocol, and CTAP plus CTHA. The breath-hold SPIO-enhanced MR imaging protocol showed a sensitivity, specificity, and accuracy equivalent to the non-breath-hold MR imaging protocol and CTAP plus CTHA.
CONCLUSIONS: As a preoperative test, SPIO-enhanced MR imaging could have the potential to replace CTAP plus CTHA in a certain clinical setting.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15870974     DOI: 10.1007/s00535-005-1553-8

Source DB:  PubMed          Journal:  J Gastroenterol        ISSN: 0944-1174            Impact factor:   7.527


  5 in total

1.  Asian Pacific Association for the Study of the Liver consensus recommendations on hepatocellular carcinoma.

Authors:  Masao Omata; Laurentius A Lesmana; Ryosuke Tateishi; Pei-Jer Chen; Shi-Ming Lin; Haruhiko Yoshida; Masatoshi Kudo; Jeong Min Lee; Byung Ihn Choi; Ronnie T P Poon; Shuichiro Shiina; Ann Lii Cheng; Ji-Dong Jia; Shuntaro Obi; Kwang Hyub Han; Wasim Jafri; Pierce Chow; Seng Gee Lim; Yogesh K Chawla; Unggul Budihusodo; Rino A Gani; C Rinaldi Lesmana; Terawan Agus Putranto; Yun Fan Liaw; Shiv Kumar Sarin
Journal:  Hepatol Int       Date:  2010-03-18       Impact factor: 6.047

2.  Accuracy of preoperative prediction of microinvasion of portal vein in hepatocellular carcinoma using superparamagnetic iron oxide-enhanced magnetic resonance imaging and computed tomography during hepatic angiography.

Authors:  Ryohei Miyata; Akihiro Tanimoto; Go Wakabayashi; Motohide Shimazu; Seishi Nakatsuka; Makio Mukai; Masaki Kitajima
Journal:  J Gastroenterol       Date:  2006-11-09       Impact factor: 7.527

3.  Detection of liver metastases secondary to pancreatic cancer: utility of combined helical computed tomography during arterial portography with biphasic computed tomography-assisted hepatic arteriography.

Authors:  Yoshiaki Ikuta; Hiroshi Takamori; Osamu Ikeda; Hiroshi Tanaka; Yasuo Sakamoto; Daisuke Hashimoto; Nobuyuki Ozaki; Osamu Nakahara; Satoshi Furuhashi; Shinya Abe; Toru Beppu; Shinya Shimada; Yasuyuki Yamashita; Hideo Baba
Journal:  J Gastroenterol       Date:  2010-07-16       Impact factor: 7.527

4.  Treatment response classification of liver metastatic disease evaluated on imaging. Are RECIST unidimensional measurements accurate?

Authors:  Michael Mantatzis; Stylianos Kakolyris; Kyriakos Amarantidis; Anastasios Karayiannakis; Panos Prassopoulos
Journal:  Eur Radiol       Date:  2009-02-24       Impact factor: 5.315

5.  Small malignant hepatic tumor detection in gadolinium- and ferucarbotran-enhanced magnetic resonance imaging: does combining ferucarbotran-enhanced T2*-weighted gradient echo and T2-weighted turbo spin echo images have additive efficacy?

Authors:  Young Kon Kim; Young Hwan Lee; Hyo Sung Kwak; Chong Soo Kim; Young Min Han
Journal:  Korean J Radiol       Date:  2008 Nov-Dec       Impact factor: 3.500

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.