Literature DB >> 15869684

Pneumopericardium and pneumothorax after permanent pacemaker implantation.

Clifford C Sebastian1, Wen-Chih Wu, Mark Shafer, Gaurav Choudhary, Pranav M Patel.   

Abstract

We present a patient with chronic obstructive pulmonary disease who developed discomfort 2 days after dual-chamber pacemaker implantation via the left cephalic vein approach. The pacer was placed with active-fixation leads without obvious complications. A computed tomography (CT) scan taken in the emergency room showed right pneumothorax and associated pneumopericardium without pneumomediastinum. A three-dimensional reconstruction of CT images confirmed the atrial lead protruding into the pleural space. This lead likely ruptured a bulla causing a pneumothorax followed by pneumopericardium through a pleuro-pericardial communication. Chest tube placement relieved both pneumothorax and pneumopericardium without the need for atrial lead extraction.

Entities:  

Mesh:

Year:  2005        PMID: 15869684     DOI: 10.1111/j.1540-8159.2005.40063.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  5 in total

1.  Pneumomediastinum and right sided pneumothorax following dual chamber-ICD implantation.

Authors:  Jonathan Rosman; Michael D Shapiro; Sam Hanon
Journal:  J Interv Card Electrophysiol       Date:  2007-02-24       Impact factor: 1.900

2.  Pneumopericardium after attempted left ventricular lead insertion.

Authors:  Adrian Baranchuk; Christopher S Simpson; Sarah Pinto; Damian P Redfearn
Journal:  Can J Cardiol       Date:  2008-08       Impact factor: 5.223

3.  Contralateral pneumothorax and pneumopericardium after dual-chamber pacemaker implantation: Mechanism, diagnosis, and treatment.

Authors:  Teerapat Nantsupawat; Jian-Ming Li; David G Benditt; Selcuk Adabag
Journal:  HeartRhythm Case Rep       Date:  2018-03-20

4.  Postural Conversion Computed Tomography for the Diagnosis of Pneumopericardium due to Perforation by the Active Atrial Lead.

Authors:  Makito Futami; Tomo Komaki; Toyonori Arinaga; Joji Morii; Makoto Sugihara; Masahiro Ogawa; Shin-Ichiro Miura
Journal:  Intern Med       Date:  2019-10-24       Impact factor: 1.271

5.  Case report: A rare complication after the implantation of a cardiac implantable electronic device: Contralateral pneumothorax with pneumopericardium and pneumomediastinum.

Authors:  Shao-Wei Lo; Ju-Yi Chen
Journal:  Front Cardiovasc Med       Date:  2022-08-18
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.