Literature DB >> 15867758

Comparative study of the surface characteristics, microstructure, and magnetic retentive forces of laser-welded dowel-keepers and cast dowel-keepers for use with magnetic attachments.

Yonglie Chao1, Li Du, Ling Yang.   

Abstract

STATEMENT OF PROBLEM: Information regarding the merits and problems associated with connecting a keeper to a dowel and coping using a laser welding technique has not been explored extensively in the dental literature.
PURPOSE: This in vitro study compared the surface characteristics, microstructure, and magnetic retentive forces for a dowel and coping-keeper mechanism fabricated using a laser welding process and a cast-to casting technique.
MATERIAL AND METHODS: Five cast-to and 6 laser-welded dowel and coping-keeper specimens were tested. Using 5 freestanding keepers as the control group, the surface characteristics and microstructures of the specimens were examined by means of stereomicroscopy, metallographic microscopy, and scanning electron microscopy (SEM). Energy-dispersive spectroscopic (EDS) microanalysis with SEM provided elemental concentration information for the test specimens. The vertical magnetic retentive forces (N) of the 3 groups were measured using a universal testing machine. The results were statistically compared using 1-way analysis of variance and the Newman-Keuls multiple range test (alpha =.05).
RESULTS: The laser-welded dowel-keeper generally maintained its original surface smoothness as well as the original microstructure. Elements diffused readily through the fusion zone. The surface of the cast dowel-keeper became rough with the formation of an oxide layer, the microstructure changed, and there was only limited elemental diffusion in the fusion zone. The average vertical magnetic retentive force of the laser-welded group, the cast group, and the control group were 4.2 +/- 0.2 N, 3.8 +/- 0.3 N, and 5.6 +/- 0.3 N, respectively. Statistically significant differences in vertical magnetic retentive force were found between the control group and both the laser-welded and cast groups (P <.01). Compared with the cast dowel-keepers, the average vertical magnetic retentive force of the laser-welded dowel-keepers was significantly higher (P <.05).
CONCLUSION: The laser welding technique had less influence on the surface characteristics, the microstructure, and the magnetic retentive forces of keepers relative to techniques that incorporate a keeper at the time of cast dowel and coping fabrication.

Mesh:

Year:  2005        PMID: 15867758     DOI: 10.1016/j.prosdent.2005.02.006

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  2 in total

Review 1.  Factors Affecting the Attractive Force of Dental Magnetic Attachment: A Literature Review for Guiding Dentists in Clinical Application.

Authors:  An-Nissa Kusumadewi; Lisda Damayanti
Journal:  Int J Dent       Date:  2022-06-14

2.  Corrosion behaviours of the dental magnetic keeper complexes made by different alloys and methods.

Authors:  Min-Ke Wu; Ning Song; Fei Liu; Liang Kou; Xiao-Wen Lu; Min Wang; Hang Wang; Jie-Fei Shen
Journal:  Int J Oral Sci       Date:  2016-09-29       Impact factor: 6.344

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.