Literature DB >> 15867450

Use of a second buddy wire during percutaneous coronary interventions: a simple solution for some challenging situations.

Francesco Burzotta1, Carlo Trani, Mario Attilio Mazzari, Rocco Mongiardo, Antonio Giuseppe Rebuzzi, Antonino Buffon, Giampaolo Niccoli, Giuseppe Biondi-Zoccai, Enrico Romagnoli, Vito Ramazzotti, Giovanni Schiavoni, Filippo Crea.   

Abstract

The buddy wire technique, i.e. the use of a second 0.014 inch guide wire placed alongside the one employed to advance balloons and stents inside the coronary artery during percutaneous coronary intervention (PCI), may help in a series of procedural challenges during PCI. Indeed, by improving both the stability of the guiding catheter and the support for balloon and stent, a buddy wire use is sometimes the simplest way to accomplish a successful procedure. In this paper, we discuss technical aspects of some specific circumstances frequently encountered during PCI, in which a buddy wire may be helpful. These include: 1) The reduction of balloon slippage during angioplasty for in-stent restenosis; 2) insufficient back-up of the guiding catheter; 3) stenting of lesions located in vessels with proximal tortuosities/angulations; 4) stenting of lesions distally located in the vessel; 5) facilitation in the positioning of distal protection devices; 6) stenting of a lesion distally located from a previously implanted stent or from a coronary segment with both calcification and sharp bend; 7) PCI on coronary arteries with anomalous origin. Because of its simplicity, low cost, and availability, the use of a buddy wire should be considered when dealing with the aforementioned conditions during PCI procedures.

Entities:  

Mesh:

Year:  2005        PMID: 15867450

Source DB:  PubMed          Journal:  J Invasive Cardiol        ISSN: 1042-3931            Impact factor:   2.022


  17 in total

1.  Novel use of the "buddy"wire.

Authors:  A O'Hare; P Brennan; J Thornton
Journal:  Interv Neuroradiol       Date:  2009-01-05       Impact factor: 1.610

2.  Using multiple buddy wires to facilitate left ventricular lead advancement in cardiac resynchronization therapy.

Authors:  Yuan-Hung Liu; Ling-Ping Lai; Jiunn-Lee Lin
Journal:  J Interv Card Electrophysiol       Date:  2007-04-20       Impact factor: 1.900

3.  Over the wire lead extraction and focused force venoplasty to regain venous access in a totally occluded subclavian vein.

Authors:  Seth J Worley; Douglas C Gohn; Robert W Pulliam
Journal:  J Interv Card Electrophysiol       Date:  2008-05-31       Impact factor: 1.900

4.  Prevalence, Presentation and Treatment of 'Balloon Undilatable' Chronic Total Occlusions: Insights from a Multicenter US Registry.

Authors:  Peter Tajti; Dimitri Karmpaliotis; Khaldoon Alaswad; Catalin Toma; James W Choi; Farouc A Jaffer; Anthony H Doing; Mitul Patel; Ehtisham Mahmud; Barry Uretsky; Aris Karatasakis; Judit Karacsonyi; Barbara A Danek; Bavana V Rangan; Subhash Banerjee; Imre Ungi; Emmanouil S Brilakis
Journal:  Catheter Cardiovasc Interv       Date:  2018-01-23       Impact factor: 2.692

5.  A case report of type VI dual left anterior descending coronary artery anomaly presenting with non-ST-segment elevation myocardial infarction.

Authors:  Yonggu Lee; Young-Hyo Lim; Jinho Shin; Kyung-Soo Kim
Journal:  BMC Cardiovasc Disord       Date:  2012-11-13       Impact factor: 2.298

6.  Entanglement due to Delayed Removal of a Buddy Wire.

Authors:  Marc Vorpahl; Melchior Seyfarth; Klaus Tiroch
Journal:  Case Rep Cardiol       Date:  2014-12-29

7.  The GuideLiner Catheter: A Useful Tool in the Armamentarium of the Interventional Cardiologist.

Authors:  Marouane Boukhris; Salvatore Azzarelli; Salvatore Davide Tomasello; Zied Ibn Elhadj; Francesco Marzà; Alfredo R Galassi
Journal:  J Tehran Heart Cent       Date:  2015-10-27

8.  When Two Is Better than One : The Buddy-wire Technique in Flow-diversion Procedures.

Authors:  Tomas Dobrocky; Hubert Lee; Patrick Nicholson; Ronit Agid; Jeremy Lynch; Saravana Kumar Swaminathan; Timo Krings; Ivan Radovanovic; Vitor Mendes Pereira
Journal:  Clin Neuroradiol       Date:  2021-07-08       Impact factor: 3.156

9.  Distal 'buddy-in-jail' technique: a complementary 'Jail with stent' method for stent delivery.

Authors:  Vincent Dangoisse; Antoine Guédès; Erwin Schroëder
Journal:  Acute Card Care       Date:  2014-03

10.  Early clinical experience with Guidezilla for transradial interventions in China.

Authors:  Min Ma; Kai-Yue Diao; Xiao-Jing Liu; Yong He
Journal:  Sci Rep       Date:  2018-04-03       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.