Literature DB >> 15866973

Polyethylene wear after total elbow arthroplasty.

Brian P Lee1, Robert A Adams, Bernard F Morrey.   

Abstract

BACKGROUND: Articular wear is considered to be a possible long-term complication of the use of stemmed, coupled elbow replacements with the capacity to correct deformity and restore function. There have been no reports on this topic, to our knowledge.
METHODS: A review of the results of 919 replacements with the semi-constrained linked Coonrad-Morrey total elbow implant, performed between 1981 and 2000, revealed that twelve patients (1.3%) had undergone an isolated exchange of the articular bushings as a result of polyethylene wear. The status of these patients was assessed clinically and radiographically.
RESULTS: The mean age of the twelve patients at the time of the initial total elbow replacement was forty-four years compared with a mean age of sixty-two years in the overall group (p < 0.001). Seven of the twelve patients had posttraumatic arthritis, and five had rheumatoid arthritis. Nine patients had extensive deformity. The group consisted of seven women and five men, and ten patients had involvement of the right dominant elbow. The mean age at the bushing revision was fifty-two years, and the bushings were revised at an average of 7.9 years after implantation. All twelve patients reported pain, and five reported crepitus or a squeaking sound. None had extensive osteolysis. The mean duration of follow-up after the bushing exchange was sixty-five months. The mean arc of motion improved from 89 degrees before the surgery to 109 degrees after it. Three of the twelve patients underwent an additional articular revision at fifty-three, fifty-four, and 136 months after the initial bushing exchange. At the time of final follow-up, all twelve patients had functioning elbows.
CONCLUSIONS: Isolated bushing exchange can be a successful revision procedure in patients with a semi-constrained linked total elbow prosthesis. Younger patients with a posttraumatic condition and/or severe pre-existing deformity are at greater risk for the development of excessive bushing wear. Patients should be cautioned against exceeding the recommended activity and lifting restrictions.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15866973     DOI: 10.2106/JBJS.D.02163

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  11 in total

Review 1.  What design and material factors impact the wear and corrosion performance in total elbow arthroplasties?

Authors:  Mark P Figgie; Timothy M Wright; Denise Drinkwater
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

2.  Complications and revisions after semi-constrained total elbow arthroplasty: a mono-centre analysis of one hundred cases.

Authors:  Julien Toulemonde; David Ancelin; Vadim Azoulay; Nicolas Bonnevialle; Michel Rongières; Pierre Mansat
Journal:  Int Orthop       Date:  2015-10-05       Impact factor: 3.075

Review 3.  Total elbow arthroplasty: history, current concepts, and future.

Authors:  Saccomanni Bernardino
Journal:  Clin Rheumatol       Date:  2010-08-04       Impact factor: 2.980

4.  Humeral amputation following total elbow arthroplasty.

Authors:  Matthew R Claxton; Matthew B Shirley; Richard F Nauert; Mark E Morrey; Joaquin Sanchez-Sotelo; Matthew T Houdek
Journal:  Int Orthop       Date:  2021-01-15       Impact factor: 3.075

Review 5.  [Revision arthroplasty of the elbow].

Authors:  K J Burkhart; G Stein; E Skouras; L P Müller
Journal:  Unfallchirurg       Date:  2010-12       Impact factor: 1.000

6.  Primary Linked Semiconstrained Total Elbow Arthroplasty for Rheumatoid Arthritis: A Single-Institution Experience with 461 Elbows Over Three Decades.

Authors:  Joaquin Sanchez-Sotelo; Yaser M K Baghdadi; Bernard F Morrey
Journal:  J Bone Joint Surg Am       Date:  2016-10-19       Impact factor: 5.284

7.  Primary elbow arthroplasty: problems and solutions.

Authors:  Joaquin Sanchez-Sotelo
Journal:  Shoulder Elbow       Date:  2016-11-16

8.  Outcome of Semi-Constrained Total Elbow Arthroplasty in Posttraumatic Conditions with Analysis of Bushing Wear on Stress Radiographs.

Authors:  Jenniefer Y Kho; Brian D Adams; Howard O'Rourke
Journal:  Iowa Orthop J       Date:  2015

9.  Why the elbow? My experience and perspective.

Authors:  Bernard Morrey
Journal:  J Clin Orthop Trauma       Date:  2021-06-09

Review 10.  Revision total elbow replacement.

Authors:  Kuen Chin; Simon Lambert
Journal:  J Clin Orthop Trauma       Date:  2021-07-03
View more