Literature DB >> 15861809

Improved method for analyzing estrogens in water by liquid chromatography-electrospray mass spectrometry.

Jianying Hu1, Haifeng Zhang, Hong Chang.   

Abstract

An improved LC-electrospray ionization MS method was established for four estrogens (17beta-estradiol (E2), estriol (E3), estrone (E1), and ethynyl estradiol (EE)) in environmental water. Almost complete separation of all estrogens was achieved on a phenyl column with methanol/water as the mobile phase. Quantification was achieved in the negative ionization mode using selected ion monitoring. The instrumental detection limits were 20-30 ng/l for the four analytes. In Milli-Q spiked water, the recoveries of the four estrogens were 72-81%, which was similar to those found for river water spiked with the corresponding deuterated estrogens. The detection limits for the four estrogens in river water were 0.1-0.2 ng/l. The method was used to detect residual estrogens in the Tonghui River, which receives water from a municipal sewage treatment plant in Beijing; E1 (1.1 ng/l) and E2 (0.2 ng/l) were detected.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15861809     DOI: 10.1016/j.chroma.2005.02.069

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

1.  A metal-organic framework of type MIL-101(Cr) for emulsification-assisted micro-solid-phase extraction prior to UHPLC-MS/MS analysis of polar estrogens.

Authors:  Sze Chieh Tan; Hian Kee Lee
Journal:  Mikrochim Acta       Date:  2019-02-09       Impact factor: 5.833

Review 2.  Reproductive drugs and environmental contamination: quantum, impact assessment and control strategies.

Authors:  Harpreet Kaur; Madhu Bala; Gulshan Bansal
Journal:  Environ Sci Pollut Res Int       Date:  2018-07-23       Impact factor: 4.223

3.  An alternative method for the determination of estrogens in surface water and wastewater treatment plant effluent using pre-column trimethylsilyl derivatization and gas chromatography/mass spectrometry.

Authors:  Yiqi Zhou; Jun Zhou; Yiping Xu; Jinmiao Zha; Mei Ma; Zijian Wang
Journal:  Environ Monit Assess       Date:  2008-10-21       Impact factor: 2.513

4.  Determination of Endocrine Disrupting Chemicals in Water and Wastewater Samples by Liquid Chromatography-Negative Ion Electrospray Ionization-Tandem Mass Spectrometry.

Authors:  Ghada Aborkhees; Renata Raina-Fulton; Ondiveerapan Thirunavokkarasu
Journal:  Molecules       Date:  2020-08-27       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.