Literature DB >> 15859618

Quantitation of trace metals in liquid samples by dried-droplet laser ablation inductively coupled plasma mass spectrometry.

Lu Yang1, Ralph E Sturgeon, Zoltán Mester.   

Abstract

A new, discrete sample introduction approach based on laser ablation (LA) is described for the quantitation of several trace metals in aqueous samples by ICPMS. Dried microdroplets of sample, previously mixed with a sodium acetate matrix, were quantitatively ablated from a polystyrene substrate. Calibration via the method of standard additions or isotope dilution provided accurate results for Ni, Cd, and Pb in drinking water and Se in a yeast extract. Compared to conventional solution nebulization, LA sample introduction provided a 2-7-fold enhancement in absolute sensitivity and transport efficiency of 2-14% for the elements examined. Estimated detection limits are 1-7-fold poorer for the dried-droplet LA technique, primarily a result of degraded precision arising from counting statistics limitations for discrete sample introduction. On the basis of the several-second half-width of the resulting transient signals, sample throughput can be in the range of 250 samples per hour. Additionally, integration of the transient signal should eliminate contributions to elemental fractionation from the LA step. Dried-droplet LA-ICPMS offers several advantages over its counterpart, ETV-ICPMS, with respect to background intensity, throughput, and ease of desorption.

Entities:  

Year:  2005        PMID: 15859618     DOI: 10.1021/ac048275a

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Element distribution over the surface of fish scales and its connection to the geochemical environment of habitats: a potential biogeochemical tag.

Authors:  TsingHai Wang; Yan-Chen Lai; Chia-Che Chiang; Yu-Rong Cheng; Yi-Kong Hsieh; Chu-Fang Wang
Journal:  Environ Monit Assess       Date:  2016-02-22       Impact factor: 2.513

2.  Recent advances in quantitative LA-ICP-MS analysis: challenges and solutions in the life sciences and environmental chemistry.

Authors:  Andreas Limbeck; Patrick Galler; Maximilian Bonta; Gerald Bauer; Winfried Nischkauer; Frank Vanhaecke
Journal:  Anal Bioanal Chem       Date:  2015-07-14       Impact factor: 4.142

3.  Radial line-scans as representative sampling strategy in dried-droplet laser ablation of liquid samples deposited on pre-cut filter paper disks.

Authors:  Winfried Nischkauer; Frank Vanhaecke; Sébastien Bernacchi; Christoph Herwig; Andreas Limbeck
Journal:  Spectrochim Acta Part B At Spectrosc       Date:  2014-11-01       Impact factor: 3.752

4.  CuII(atsm) Attenuates Neuroinflammation.

Authors:  Xin Yi Choo; Jeffrey R Liddell; Mikko T Huuskonen; Alexandra Grubman; Diane Moujalled; Jessica Roberts; Kai Kysenius; Lauren Patten; Hazel Quek; Lotta E Oikari; Clare Duncan; Simon A James; Lachlan E McInnes; David J Hayne; Paul S Donnelly; Eveliina Pollari; Suvi Vähätalo; Katarína Lejavová; Mikko I Kettunen; Tarja Malm; Jari Koistinaho; Anthony R White; Katja M Kanninen
Journal:  Front Neurosci       Date:  2018-09-24       Impact factor: 4.677

  4 in total