Literature DB >> 15859604

Genosensor based on a platinum(II) complex as electrocatalytic label.

David Hernández-Santos1, María Begoña González-García, Agustín Costa-García.   

Abstract

Voltammetric genosensors on streptavidin-modified screen-printed carbon electrodes (SPCEs) for the detection of virulence nucleic acid determinants of pneumolysin (ply) and autolysin (lytA) genes, exclusively present on the genome of the human pathogen Streptococcus pneumoniae, were described. The oligonucleotide probes were immobilized on electrochemically pretreated SPCEs through the streptavidin/biotin reaction. After that, the hybridization reaction was carried out with labeled complementary targets on the electrode surface. The ply and lytA targets were labeled using the universal linkage system, which consists of the use of a platinum(II) complex that acts as coupling agent between targets and a, usually fluorescent, molecule label. In this case, the platinum(II) complex acts as a label itself because the analytical signal is achieved by measuring chronoamperometrically the current generated by the hydrogen evolution catalyzed by platinum. In nonstringent experimental conditions, these genosensors can detect 24.5 fmol of 20-mer oligonucleotide target and discriminate between a complementary oligo and an oligo with a three-base mismatch. In presence of 25% formamide in the hybridization buffer, a single-base mismatch on the oligonucleotide target can be detected.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15859604     DOI: 10.1021/ac048091w

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

Review 1.  State-of-the-art of (bio)chemical sensor developments in analytical Spanish groups.

Authors:  María Reyes Plata; Ana María Contento; Angel Ríos
Journal:  Sensors (Basel)       Date:  2010-03-24       Impact factor: 3.576

2.  DNA hybridization sensor based on aurothiomalate electroactive label on glassy carbon electrodes.

Authors:  Alfredo de la Escosura-Muñiz; María Begoña González-García; Agustín Costa-García
Journal:  Biosens Bioelectron       Date:  2006-06-09       Impact factor: 10.618

3.  DNA single-base mismatch study with an electrochemical enzymatic genosensor.

Authors:  Patricia Abad-Valle; M Teresa Fernández-Abedul; Agustín Costa-García
Journal:  Biosens Bioelectron       Date:  2006-09-01       Impact factor: 10.618

4.  Methylene blue covalently attached to single stranded DNA as electroactive label for potential bioassays.

Authors:  Raquel García-González; Agustín Costa-García; M Teresa Fernández-Abedul
Journal:  Sens Actuators B Chem       Date:  2013-10-16       Impact factor: 7.460

5.  Electroactive intercalators for DNA analysis on microchip electrophoresis.

Authors:  Mario Castaño-Alvarez; M Teresa Fernández-Abedul; Agustín Costa-García
Journal:  Electrophoresis       Date:  2007-12       Impact factor: 3.535

6.  DNA hybridization biosensors using polylysine modified SPCEs.

Authors:  María Díaz-González; Alfredo de la Escosura-Muñiz; María Begoña González-García; Agustín Costa-García
Journal:  Biosens Bioelectron       Date:  2007-12-08       Impact factor: 10.618

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.