Literature DB >> 15852993

Initial distribution volume of glucose is correlated with intrathoracic blood volume in hypovolaemia and following volume loading in dogs.

H Nakamura1, H Ishihara, H Okawa, Y Yatsu, T Tsubo, A Matsuki.   

Abstract

BACKGROUND AND
OBJECTIVE: Initial distribution volume of glucose (IDVG) reliably measures the central extracellular fluid volume in the presence of fluid gain or loss. We hypothesized that IDVG has a close relationship with intrathoracic blood volume (ITBV), which has recently been used as an indicator of cardiac preload. We therefore examined whether IDVG can correlate with ITBV in various fluid volume states.
METHODS: Fourteen anaesthetized mongrel dogs were mechanically ventilated. ITBV and cardiac output were measured by single transpulmonary thermodilution technique. IDVG and indocyanine green derived plasma volume (PV-ICG) were determined by the administration of 100 mg kg(-1) glucose and 0.5 mg kg(-1) indocyanine green solutions, respectively, and calculated by applying a one-compartment model. Three sets of measurements were performed before and after haemorrhage (30 mL kg(-1) and subsequent fluid volume loading (90 mL kg(-1) of lactated Ringer's solution).
RESULTS: A linear correlation was observed between IDVG and ITBV (r2 = 0.52, n = 42, P < 0.001) and between PV-ICG and ITBV (r2 = 0.44, n = 42, P < 0.001) throughout the procedures. A linear correlation was also observed between changes in IDVG and those in ITBV (r2 = 0.76, n = 28, P < 0.001). The ITBV/IDVG ratio during normovolaemia was 0.26 +/- 0.04, which remained unchanged during the procedure.
CONCLUSION: Results showed that that IDVG has a linear correlation with ITBV, and support the concept that IDVG measurement has potential as a surrogate measure of ITBV in various fluid volume states.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15852993     DOI: 10.1017/s0265021505000359

Source DB:  PubMed          Journal:  Eur J Anaesthesiol        ISSN: 0265-0215            Impact factor:   4.330


  3 in total

1.  Assessment of cardiac preload status by pulse pressure variation in patients after anesthesia induction: comparison with central venous pressure and initial distribution volume of glucose.

Authors:  Zhiyong He; Hui Qiao; Wei Zhou; Yun Wang; Zhendong Xu; Xuehua Che; Jun Zhang; Weimin Liang
Journal:  J Anesth       Date:  2011-09-21       Impact factor: 2.078

Review 2.  Year in review 2005: critical care--cardiology.

Authors:  Timothy Gatheral; E David Bennett
Journal:  Crit Care       Date:  2006       Impact factor: 9.097

3.  Initial distribution volume of glucose can be approximated using a conventional glucose analyzer in the intensive care unit.

Authors:  Hironori Ishihara; Hitomi Nakamura; Hirobumi Okawa; Hajime Takase; Toshihito Tsubo; Kazuyoshi Hirota
Journal:  Crit Care       Date:  2005-02-11       Impact factor: 9.097

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.