Literature DB >> 15852131

Junction-less reference electrode for potentiometric measurements obtained by buffering pH in a conducting polymer matrix.

Teresa Blaz1, Jan Migdalski, Andrzej Lewenstam.   

Abstract

A reference electrode for potentiometric measurements based on conducting polymers (CP) doped with pH buffering ligands is described. Both the CPs and doping ligands are selected and adjusted in such a way that possible ionic and redox sensitivity is hampered, while the pH buffering property of the CP film is exposed. In this way, the electric potential drop at the conducting polymer|solution interface is stabilized and close to constant over a certain pH range. The electrode behaves as a pseudo-reference electrode in amphiprotic solvents or their mixtures, e.g. water-alcohol mixtures. For the first time titration of sulfates with lead(ii) in water-methanol solution using two "plastic" electrodes, CP-based Pb(2+)-sensitive indicator and CP-based reference electrode, is shown. Because the electrode is junction-less it may easily be miniaturized and maintained and thus may serve in frontier applications of sensors.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15852131     DOI: 10.1039/b418384c

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  6 in total

Review 1.  Electrochemical sensors.

Authors:  Eric Bakker; Yu Qin
Journal:  Anal Chem       Date:  2006-06-15       Impact factor: 6.986

2.  Long-Time Evaluation of Solid-State Composite Reference Electrodes.

Authors:  Slim Blidi; Kim Granholm; Tomasz Sokalski; Zekra Mousavi; Andrzej Lewenstam; Ivo Leito; Johan Bobacka
Journal:  Membranes (Basel)       Date:  2022-05-30

3.  Solid-state reference electrodes based on carbon nanotubes and polyacrylate membranes.

Authors:  F Xavier Rius-Ruiz; Anna Kisiel; Agata Michalska; Krzystof Maksymiuk; Jordi Riu; F Xavier Rius
Journal:  Anal Bioanal Chem       Date:  2011-02-12       Impact factor: 4.142

4.  RuO₂ pH Sensor with Super-Glue-Inspired Reference Electrode.

Authors:  Wade Lonsdale; Magdalena Wajrak; Kamal Alameh
Journal:  Sensors (Basel)       Date:  2017-09-06       Impact factor: 3.576

5.  A Multi-Parametric Device with Innovative Solid Electrodes for Long-Term Monitoring of pH, Redox-Potential and Conductivity in a Nuclear Waste Repository.

Authors:  Jordan Daoudi; Stephanie Betelu; Theodore Tzedakis; Johan Bertrand; Ioannis Ignatiadis
Journal:  Sensors (Basel)       Date:  2017-06-13       Impact factor: 3.576

6.  Reference Electrodes with Polymer-Based Membranes-Comprehensive Performance Characteristics.

Authors:  Peter Lingenfelter; Bartosz Bartoszewicz; Jan Migdalski; Tomasz Sokalski; Mirosław M Bućko; Robert Filipek; Andrzej Lewenstam
Journal:  Membranes (Basel)       Date:  2019-11-29