Literature DB >> 15851084

Screening for unilateral intracranial abnormalities using near infrared spectroscopy: a preliminary report.

Sheeja V Francis1, G Ravindran, K Visvanathan, K Ganapathy.   

Abstract

Near infrared spectroscopy (NIRS) is being increasingly used for medical applications, including neurosurgical care. This preliminary report describes the use of a low cost, indigenous, non-invasive system where NIRS is used to identify superficial unilateral intracranial abnormalities. The optical density (OD) over each hemisphere was initially studied in 50 normal volunteers. The specificity, sensitivity, reliability and reproducibility of the NIRS generated from the developed equipment in detecting OD were thus confirmed. The OD over each hemisphere was then measured in 71 other individuals, immediately after a computed tomography (CT) scan of the brain was performed. Data was statistically analysed to find the average OD difference (compared to the opposite side) of the various intracranial compartments. Differences in OD suggested a unilateral intracranial abnormality. All those in whom OD differences were detected with the NIRS system had unilateral abnormalities on the CT scan. None of the 53 patients who had a normal CT scan had significant differences in OD.

Entities:  

Mesh:

Year:  2005        PMID: 15851084     DOI: 10.1016/j.jocn.2004.06.009

Source DB:  PubMed          Journal:  J Clin Neurosci        ISSN: 0967-5868            Impact factor:   1.961


  9 in total

Review 1.  Severe Cranioencephalic Trauma: Prehospital Care, Surgical Management and Multimodal Monitoring.

Authors:  Luis Rafael Moscote-Salazar; Andres M Rubiano; Hernando Raphael Alvis-Miranda; Willem Calderon-Miranda; Gabriel Alcala-Cerra; Marco Antonio Blancas Rivera; Amit Agrawal
Journal:  Bull Emerg Trauma       Date:  2016-01

Review 2.  Italian guidelines on the assessment and management of pediatric head injury in the emergency department.

Authors:  Liviana Da Dalt; Niccolo' Parri; Angela Amigoni; Agostino Nocerino; Francesca Selmin; Renzo Manara; Paola Perretta; Maria Paola Vardeu; Silvia Bressan
Journal:  Ital J Pediatr       Date:  2018-01-15       Impact factor: 2.638

3.  The utility of near infrared spectroscopy in detecting intracranial hemorrhage in children.

Authors:  Rosanne Salonia; Michael J Bell; Patrick M Kochanek; Rachel P Berger
Journal:  J Neurotrauma       Date:  2012-01-26       Impact factor: 5.269

Review 4.  Near-Infrared Spectroscopy in the Monitoring of Adult Traumatic Brain Injury: A Review.

Authors:  David J Davies; Zhangjie Su; Michael T Clancy; Samuel J E Lucas; Hamid Dehghani; Ann Logan; Antonio Belli
Journal:  J Neurotrauma       Date:  2015-04-17       Impact factor: 5.269

5.  The use of handheld near-infrared device (Infrascanner)for detecting intracranial haemorrhages in children with minor head injury.

Authors:  Silvia Bressan; Marco Daverio; Francesco Martinolli; Daniele Dona'; Federica Mario; Ivan P Steiner; Liviana Da Dalt
Journal:  Childs Nerv Syst       Date:  2014-03       Impact factor: 1.475

Review 6.  Application of optical methods in the monitoring of traumatic brain injury: A review.

Authors:  Wojciech Weigl; Daniel Milej; Dariusz Janusek; Stanisław Wojtkiewicz; Piotr Sawosz; Michał Kacprzak; Anna Gerega; Roman Maniewski; Adam Liebert
Journal:  J Cereb Blood Flow Metab       Date:  2016-09-07       Impact factor: 6.200

7.  Intracranial Hematoma Detection by Near Infrared Spectroscopy in a Helicopter Emergency Medical Service: Practical Experience.

Authors:  Patrick Schober; Sebastiaan M Bossers; Lothar A Schwarte
Journal:  Biomed Res Int       Date:  2017-06-22       Impact factor: 3.411

8.  Phantom-based evaluation of near-infrared intracranial hematoma detector performance.

Authors:  Jianting Wang; Jonathan Lin; Yu Chen; Cristin G Welle; T Joshua Pfefer
Journal:  J Biomed Opt       Date:  2019-04       Impact factor: 3.170

9.  Evaluation of near infrared spectroscopy as screening tool for detecting intracranial hematomas in patients with traumatic brain injury.

Authors:  V Trehan; Vikas Maheshwari; S V Kulkarni; Sanjeev Kapoor; Anurakshat Gupta
Journal:  Med J Armed Forces India       Date:  2017-11-27
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.