Literature DB >> 1584861

Reproducibility and accuracy of angle measurements obtained under static conditions with the Motion Analysis video system.

D W Vander Linden1, S J Carlson, R L Hubbard.   

Abstract

The development of computerized and semi-automated motion analysis systems has made the study of human motion more widely available in research and clinical settings. Although many of these systems are currently used by physical therapists, the accuracy and reproducibility of some of these systems in estimating joint angles have not been reported. In this study, the accuracy and reproducibility of angle measurements obtained by use of the Motion Analysis video system were evaluated under static conditions using a standard goniometer. Reflective markers placed on a goniometer were recorded by two video cameras at 17 angles, from 20 to 180 degrees, in 10-degree increments. Recordings of the goniometer were made at three locations within the field of view of the cameras. The intraclass correlation coefficient for each location tested was .99. Average within-trial variability was less than 0.4 degree at all locations. A linear regression of the system-calculated angles and reference angles for all locations had slopes near unity (ie, 1) and intercepts that were not statistically different from zero. A preliminary evaluation of the system under dynamic conditions revealed that distances were slightly underestimated, regardless of where the movement occurred within the calibration cube.

Entities:  

Mesh:

Year:  1992        PMID: 1584861     DOI: 10.1093/ptj/72.4.300

Source DB:  PubMed          Journal:  Phys Ther        ISSN: 0031-9023


  5 in total

1.  The effect of an inclined landing surface on biomechanical variables during a jumping task.

Authors:  Marshall Hagins; Evangelos Pappas; Ian Kremenic; Karl F Orishimo; Andrew Rundle
Journal:  Clin Biomech (Bristol, Avon)       Date:  2007-09-10       Impact factor: 2.063

2.  Test-retest reliability and inter-tester reliability of kinematic data from a three-dimensional gait analysis system.

Authors:  Hitoshi Tsushima; Meg E Morris; Jennifer McGinley
Journal:  J Jpn Phys Ther Assoc       Date:  2003

3.  The Kinematic and Kinetic Responses of the Trunk and Lower Extremity Joints during Walking with and without the Spinal Orthosis.

Authors:  Chenyan Wang; Xiaona Li; Yuan Guo; Weijin Du; Hongmei Guo; Weiyi Chen
Journal:  Int J Environ Res Public Health       Date:  2022-06-06       Impact factor: 4.614

4.  Determination of rigid body registration marker error from edge error.

Authors:  Clark R Andersen
Journal:  J Biomech       Date:  2009-03-09       Impact factor: 2.712

5.  Evaluation of Sagittal Spine-Pelvis-Lower Limb Alignment in Elderly Women with Pelvic Retroversion while Standing and Walking Using a Three-Dimensional Musculoskeletal Model.

Authors:  Ken Sasaki; Michio Hongo; Naohisa Miyakoshi; Toshiki Matsunaga; Shin Yamada; Hiroaki Kijima; Yoichi Shimada
Journal:  Asian Spine J       Date:  2017-08-07
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.