Literature DB >> 15846763

Power Doppler vascularity index for predicting malignancy of adnexal masses.

H Marret1, S Sauget, B Giraudeau, G Body, F Tranquart.   

Abstract

OBJECTIVE: To assess the performance of a power Doppler vascularity index in the preoperative diagnosis of ovarian malignancy.
METHODS: Adnexal masses (n = 101) were examined prospectively with power Doppler ultrasonography before surgical treatment. The tumor vascularity index (power Doppler index, PDI) was determined by quantification of the number of pixels in a defined region of interest according to the formula: number of colored pixels/(total number of pixels minus the number of pixels in the fluid or avascular areas). It was estimated on selected frames of the tumors using an in-house color-quantifying program added to MATLAB 6.0 software. Inter- and intraobserver reproducibilities of PDI assessment were evaluated. Intratumoral blood flow velocity waveforms were obtained to determine the lowest resistance index (RI). A subjective visual score of power Doppler signals in the tumor was used to classify it as having low, moderate or high vascularity. The discriminatory ability of this score was compared to that of RI and PDI measurement.
RESULTS: Histology identified 23 malignant and 78 benign lesions. The PDI was considerably higher in malignant than in benign lesions (0.34 +/- 0.04 vs. 0.12 +/- 0.06; P < 0.001). The intra- and interobserver variabilities of PDI were low (intraclass correlation coefficients of 0.99 and 0.97, respectively). The PDI cut-off value to differentiate malignant from benign tumors was set at 0.265 (26.5% of the tumor being colored). Using this cut-off, sensitivity and specificity were 100% (95% CI, 87.8-100.0) and 97.4% (95% CI, 91.0-99.7) compared to 78.3% (95% CI, 56.3-92.5) and 83.1% (95% CI, 72.9-90.7) for RI (cut-off value of 0.53) and 78.3% (95% CI, 56.3-92.5) and 94.9% (95% CI, 87.4-98.6) for visual scoring. Logistic regression demonstrated that PDI was the best parameter for differentiating between malignant and benign tumors.
CONCLUSION: The power Doppler vascularity index obtained using customized color quantifying software has high diagnostic value in discriminating between benign and malignant adnexal masses.

Entities:  

Mesh:

Year:  2005        PMID: 15846763     DOI: 10.1002/uog.1893

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  3 in total

1.  Current diagnostic approach to patients with adnexal masses: which tools are relevant in routine praxis?

Authors:  Milan M Terzic; Jelena Dotlic; Ivana Likic; Nebojsa Ladjevic; Natasa Brndusic; Nebojsa Arsenovic; Sanja Maricic; Tihomir Mihailovic; Sasa Andrijasevic
Journal:  Chin J Cancer Res       Date:  2013-02       Impact factor: 5.087

2.  Diagnostic value of 3D power Doppler ultrasound in the characterization of thyroid nodules

Authors:  Ayşegül Cansu; Emine Ayan; Sibel Kul; İlker Eyüboğlu; Şükrü Oğuz; Sevdegül Mungan
Journal:  Turk J Med Sci       Date:  2019-06-18       Impact factor: 2.925

3.  Hemodynamic Changes in the Masseter and Superior Orbicularis Oris Muscles before and after Exercise Load: A Comparison between Young Adult Women and Middle-Aged to Old Adult Women.

Authors:  Keiko Okamoto; Chihiro Tanikawa; Kenji Takada
Journal:  Int J Dent       Date:  2022-08-27