BACKGROUND: Providing effective positive pressure ventilation is the single most important component of successful neonatal resuscitation. Ventilation is frequently initiated with a manual resuscitation bag and face-mask (BMV) followed by endotracheal intubation (ETT) if depression continues. These techniques may be difficult to perform successfully resulting in prolonged resuscitation or severe neonatal depression. The laryngeal mask airway (LMA) may achieve initial ventilation and successful resuscitation faster than a bag-mask device or endotracheal intubation.
OBJECTIVES: Among newborns requiring positive pressure ventilation for resuscitation, is effective ventilation and successful resuscitation achieved faster with the LMA compared with either BMV or ETT? SEARCH STRATEGY: The Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library, Issue 3, 2004), MEDLINE (1966-November 2004), Pre-MEDLINE (November 15, 2004), CINAHL 1982-November 2004), reference lists of published trials, and Society for Pediatric Research abstracts were searched. Experts were contacted for additional references. SELECTION CRITERIA: Randomised and quasi-randomised trials DATA COLLECTION AND ANALYSIS: Two reviewers independently evaluated studies, assessed methodologic quality, and extracted data using the Cochrane Neonatal Review Group criteria. Categorical treatment effects were described as relative risks and risk differences and continuous treatment effects were described as the mean difference. There were insufficient data to perform pooled analyses. MAIN
RESULTS: No eligible studies compared the LMA with BMV. One small randomised controlled trial comparing the LMA with ETT when BMV had been unsuccessful was included. There was no statistically significant difference between the LMA and ETT with the exception of a clinically insignificant difference in time to complete insertion of the device favouring the ETT. AUTHORS'
CONCLUSIONS: The LMA can achieve effective ventilation during neonatal resuscitation in a time-frame consistent with current guidelines. There is no evidence to evaluate the relative efficacy and safety of the LMA compared with BMV as the primary airway device. A single, small randomised controlled trial found no clinically significant difference between the LMA and ETT when BMV was unsuccessful. Case series and case reports suggest that the LMA can provide an effective rescue airway during resuscitation if both BMV and ETT have been unsuccessful. A well-designed randomised controlled trial comparing the LMA with BMV during neonatal resuscitation is warranted.

Entities:  

Mesh:

Year:  2005        PMID: 15846656     DOI: 10.1002/14651858.CD003314.pub2

Source DB:  PubMed          Journal:  Cochrane Database Syst Rev        ISSN: 1361-6137


  10 in total

Review 1.  Potential and Limitations of Cochrane Reviews in Pediatric Cardiology: A Systematic Analysis.

Authors:  Martin Poryo; Sara Khosrawikatoli; Hashim Abdul-Khaliq; Sascha Meyer
Journal:  Pediatr Cardiol       Date:  2017-02-27       Impact factor: 1.655

2.  Laryngeal Mask Airway for neonatal resuscitation in a developing country: evaluation of an educational intervention. Neonatal LMA: an educational intervention in DRC.

Authors:  Vincenzo Zanardo; Alphonse Simbi; Massimo Micaglio; Francesco Cavallin; Leon Tshilolo; Daniele Trevisanuto
Journal:  BMC Health Serv Res       Date:  2010-08-31       Impact factor: 2.655

Review 3.  Laryngeal mask airway versus bag-mask ventilation or endotracheal intubation for neonatal resuscitation.

Authors:  Mosarrat J Qureshi; Manoj Kumar
Journal:  Cochrane Database Syst Rev       Date:  2018-03-15

4.  LMA Supreme for neonatal resuscitation: study protocol for a randomized controlled trial.

Authors:  Daniele Trevisanuto; Francesco Cavallin; Veronica Mardegan; Nguyen Ngoc Loi; Nguyen Viet Tien; Tran Dieu Linh; Tran Dinh Chien; Nicoletta Doglioni; Lino Chiandetti; Luciano Moccia
Journal:  Trials       Date:  2014-07-15       Impact factor: 2.279

5.  Pilot manikin study showed that a supraglottic airway device improved simulated neonatal ventilation in a low-resource setting.

Authors:  Nicolas J Pejovic; Daniele Trevisanuto; Jolly Nankunda; Thorkild Tylleskär
Journal:  Acta Paediatr       Date:  2016-12       Impact factor: 2.299

6.  Neonatal resuscitation using a laryngeal mask airway: a randomised trial in Uganda.

Authors:  Nicolas J Pejovic; Daniele Trevisanuto; Clare Lubulwa; Susanna Myrnerts Höök; Francesco Cavallin; Josaphat Byamugisha; Jolly Nankunda; Thorkild Tylleskär
Journal:  Arch Dis Child       Date:  2017-09-14       Impact factor: 3.791

Review 7.  Essential childbirth and postnatal interventions for improved maternal and neonatal health.

Authors:  Rehana A Salam; Tarab Mansoor; Dania Mallick; Zohra S Lassi; Jai K Das; Zulfiqar A Bhutta
Journal:  Reprod Health       Date:  2014-08-21       Impact factor: 3.223

8.  Essential interventions: implementation strategies and proposed packages of care.

Authors:  Zohra S Lassi; Rohail Kumar; Tarab Mansoor; Rehana A Salam; Jai K Das; Zulfiqar A Bhutta
Journal:  Reprod Health       Date:  2014-08-21       Impact factor: 3.223

9.  Novel technique for placement of laryngeal mask airway in difficult pediatric airways.

Authors:  Fatemeh Roodneshin; Mahvash Agah
Journal:  Tanaffos       Date:  2011

Review 10.  Small is the new big: An overview of newer supraglottic airways for children.

Authors:  Rakhee Goyal
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2015 Oct-Dec
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.