Simple confirmatory assay for analyzing residues of aminoglycoside antibiotics in bovine milk: hot water extraction followed by liquid chromatography-tandem mass spectrometry.

Sara Bogialli1, Roberta Curini, Antonio Di Corcia, Aldo Laganà, Monica Mele, Manuela Nazzari.   

Abstract

A simple, selective and sensitive procedure for determining nine widely used aminoglycoside antibiotics (AGs) in bovine whole milk is presented. It is based on matrix solid-phase dispersion with heated water, at 70 degrees C, as extractant followed by liquid chromatography (LC)-tandem mass spectrometry (MS) using an electrospray ion source. After acidification and filtration, 0.2 ml of the aqueous extract was injected into the LC column. MS data acquisition was performed in the multi reaction monitoring mode, selecting two (three, when possible) precursor ion > product ion transitions for each target compound. Analyte recoveries ranged between 70 and 92%. Using aminosidine (an AG not used in veterinary medicine) as surrogate internal standard, the accuracy of the method at three spike levels varied between 80 and 107% with R.S.D. not larger than 11%. The limits of quantification were between 2 ng/ml (apramycin) and 13 ng/ml (streptomycin). They are well below the tolerance levels set by both the European Union and the U.S. Food and Drug Administration.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15844513     DOI: 10.1016/j.chroma.2004.10.033

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  1 in total

1.  Study on microwave assisted extraction of chrysophanol and its intervention in biofilm formation of Streptococcus suis.

Authors:  Jing-Wen Bai; Xing-Ru Chen; Yang Tang; Wen-Qiang Cui; Da-Long Li; Bello-Onaghise God'spower; Yu Yang
Journal:  RSC Adv       Date:  2019-09-17       Impact factor: 4.036

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.