Literature DB >> 15844021

Endoscopic argon plasma trimming of biliary and gastrointestinal metallic stents.

G Vanbiervliet1, T Piche, F X Caroli-Bosc, R Dumas, E P Peten, P M Huet, A Tran, J F Demarquay.   

Abstract

BACKGROUND AND STUDY AIMS: The aim of this study was to assess the feasibility and efficiency of plasma argon trimming of gastrointestinal and biliary metallic stents. PATIENTS AND METHODS: A total of 31 patients underwent plasma argon trimming of their metallic stents (14 women, 17 men; mean +/- SD age 73 +/- 12.2 years, range 46 - 96 years). Of these 31 patients, 24 had had covered or noncovered Unistep Wallstents placed in the biliary tract (13 patients with pancreatic neoplasms, five patients with Vater ampulloma, five patients with biliary tract carcinoma and one patient with chronic calcifiying pancreatitis); three patients had noncovered Enteral Unistep Wallstents (pyloroduodenal); two patients with obstructive colorectal carcinoma had a noncovered Bard Memotherm stent inserted; and two patients had noncovered Ultraflex stents placed for esophageal carcinoma. Endoscopic trimming of the stents was performed under propofol-induced general anesthesia, with the power set at 70 - 80 watts and an argon flow of 0.8 liters/minute.
RESULTS: Complete and satisfactory trimming of the stents was possible, without complications (mean follow-up 15.8 months), in all patients except one, a patient with a covered biliary Wallstent. In 13 patients with biliary or Enteral Wallstents the trimming procedure was preventive. In eight patients with ulceration and/or hemorrhage (duodenal or rectal), healing was achieved after stent trimming and epinephrine (adrenaline) injection followed by electrocoagulation. Stent trimming restored patency of the duodenal lumen in six patients and of the esophageal lumen in two patients, and was done to allow insertion of a biliary stent in one patient whose duodenal stent was covering the papilla. In one patient with rectal tenesmus, stent shortening resulted in complete resolution of symptoms.
CONCLUSIONS: Endsocopic plasma argon trimming of metallic stents is an efficient procedure which allows easy, reproducible and well-tolerated correction of complications that arise due to these prostheses.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15844021     DOI: 10.1055/s-2005-860989

Source DB:  PubMed          Journal:  Endoscopy        ISSN: 0013-726X            Impact factor:   10.093


  11 in total

1.  Endoscopic removal and trimming of distal self-expandable metallic biliary stents.

Authors:  Kentaro Ishii; Takao Itoi; Atsushi Sofuni; Fumihide Itokawa; Takayoshi Tsuchiya; Toshio Kurihara; Shujiro Tsuji; Nobuhito Ikeuchi; Junko Umeda; Fuminori Moriyasu; Akihiko Tsuchida
Journal:  World J Gastroenterol       Date:  2011-06-07       Impact factor: 5.742

2.  Stent-in-stent through a side hole to prevent biliary metallicstent migration.

Authors:  Wiriyaporn Ridtitid; Rungsun Rerknimitr; Surachai Amornsawadwattana; Yuwadee Ponauthai; Pinit Kullavanijaya
Journal:  World J Gastrointest Endosc       Date:  2011-03-16

3.  Trimming of a migrated metal stent for malignant colonic stricture using argon plasma coagulation.

Authors:  Kiran Venkat Rao; Gagan Deep Beri; Weizheng William Wang
Journal:  World J Gastrointest Endosc       Date:  2010-02-16

Review 4.  [Endoscopic palliation of esophageal and bronchial carcinomas].

Authors:  J Gottlieb; J Wedemeyer
Journal:  Internist (Berl)       Date:  2010-03       Impact factor: 0.743

5.  Trimming of a Broken Migrated Biliary Metal Stent with the Nd:YAG Laser.

Authors:  I Zuber-Jerger; F Kullmann
Journal:  Case Rep Gastroenterol       Date:  2009-03-28

6.  Trimming of a Migrated Biliary Nitinol Stent Using Argon Plasma.

Authors:  Hiroyuki Matsubayashi; Noriaki Hasuike; Masaki Tanaka; Kohei Takizawa; Yuichiro Yamaguchi; Hiroyuki Ono
Journal:  Case Rep Gastroenterol       Date:  2009-07-31

7.  Endoscopic multiple metal stenting for the treatment of enteral leaks near the biliary orifice: A novel effective rescue procedure.

Authors:  Massimiliano Mutignani; Lorenzo Dioscoridi; Stefanos Dokas; Paolo Aseni; Pietro Carnevali; Edoardo Forti; Raffaele Manta; Mariano Sica; Alberto Tringali; Francesco Pugliese
Journal:  World J Gastrointest Endosc       Date:  2016-08-10

8.  Endoscopic Removal of a Proximally Migrated Metal Stent during Balloon Sweeping after Stent Trimming.

Authors:  Nam Jun Cho; Tae Hoon Lee; Sang-Heum Park; Han Min Lee; Kyung Hee Hyun; Suck-Ho Lee; Il-Kwun Chung; Sun-Joo Kim
Journal:  Clin Endosc       Date:  2013-07-31

9.  Argon Plasma Coagulation for Extraction of an Impacted Trapezoid Basket in the Pancreatic Duct.

Authors:  Treta Purohit; Mrinal Garg; Abhijit Kulkarni; Shyam Thakkar
Journal:  ACG Case Rep J       Date:  2015-04-10

Review 10.  Recent advances of biliary stent management.

Authors:  Mitsuhiro Kida; Shiro Miyazawa; Tomohisa Iwai; Hiroko Ikeda; Miyoko Takezawa; Hidehiko Kikuchi; Maya Watanabe; Hiroshi Imaizumi; Wasaburo Koizumi
Journal:  Korean J Radiol       Date:  2012-04-23       Impact factor: 3.500

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.