Radiation exposure to the hands of orthopaedic surgeons: are we underestimating the risk?

M A Hafez1, R M Smith, S J Matthews, G Kalap, K P Sherman.   

Abstract

INTRODUCTION: Previous studies reported that the radiation exposure to the hands of orthopaedic surgeons was far below the acceptable limit. However, the risk could have been underestimated as some factors were overlooked, namely monitoring trainees during average workload, placing dosimeters over the most susceptible locations, measuring the cumulative dosage of radiation and considering the dose limit for non-classified workers.
MATERIALS AND METHODS: We performed a prospective study in two centres to estimate the radiation dose to the hands of two consultant trauma surgeons and two trainees (one assisting and one operating) while performing 47 fluoroscopy-assisted procedures. We used validated thermoluminescent dosimeters (TLDs) rings and fingerstalls for monitoring the cumulative dosage.
RESULTS: Trainees were at higher risk while performing intramedullary nailing and during assistance. Higher radiation doses were recorded from dominant index fingers and particularly fingertips.
CONCLUSION: The risk of radiation exposure appears to be higher than previously reported. Fingertips are more susceptible to radiation exposure and should therefore be monitored in forthcoming studies.

Entities:  

Mesh:

Year:  2005        PMID: 15843947     DOI: 10.1007/s00402-005-0807-5

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  17 in total

Review 1.  Occupational radiation doses to operators performing fluoroscopically-guided procedures.

Authors:  Kwang Pyo Kim; Donald L Miller; Amy Berrington de Gonzalez; Stephen Balter; Ruth A Kleinerman; Evgenia Ostroumova; Steven L Simon; Martha S Linet
Journal:  Health Phys       Date:  2012-07       Impact factor: 1.316

2.  Olecranon anatomy: Use of a novel proximal interlocking screw for intramedullary nailing, a cadaver study.

Authors:  Fatih Küçükdurmaz; Necdet Saglam; Ismail Ağır; Cengiz Sen; Fuat Akpınar
Journal:  World J Orthop       Date:  2013-07-18

3.  [Evaluation of a 2D fluoroscopy-based navigation system for insertion of femoral neck screws. An experimental study].

Authors:  M C Müller; P Belei; M de la Fuente; M Strake; K Kabir; O Weber; C Burger; K Radermacher; D C Wirtz
Journal:  Unfallchirurg       Date:  2012-09       Impact factor: 1.000

4.  Radiation safety knowledge and practices among Irish orthopaedic trainees.

Authors:  M Nugent; O Carmody; S Dudeney
Journal:  Ir J Med Sci       Date:  2014-04-23       Impact factor: 1.568

Review 5.  Occupational health related concerns among surgeons.

Authors:  Anjuman Gul Memon; Zahid Naeem; Atif Zaman; Faryal Zahid
Journal:  Int J Health Sci (Qassim)       Date:  2016-04

6.  Fluoroscopic freehand and electromagnetic-guided targeting system for distal locking screws of humeral intramedullary nail.

Authors:  P Persiani; M Gurzi; O Moreschini; G Di Giacomo; C Villani
Journal:  Musculoskelet Surg       Date:  2016-11-22

7.  Generic Implant Positioning Technology Based on Hole Projections in X-Ray Images.

Authors:  Markus Windolf; Robert Geoff Richards
Journal:  J Med Device       Date:  2021-03-23       Impact factor: 0.743

8.  Dosimetry during intramedullary nailing of the tibia.

Authors:  George Kirousis; Harry Delis; Panagiotis Megas; Elias Lambiris; George Panayiotakis
Journal:  Acta Orthop       Date:  2009-10       Impact factor: 3.717

Review 9.  Radiation exposure of eyes, thyroid gland and hands in orthopaedic staff: a systematic review.

Authors:  Chandrasekharan Nair Kesavachandran; Frank Haamann; Albert Nienhaus
Journal:  Eur J Med Res       Date:  2012-10-30       Impact factor: 2.175

10.  2D-fluoroscopic based navigation for Gamma 3 nail insertion versus conventional procedure- a feasibility study.

Authors:  A Wilharm; I Marintschev; G O Hofmann; F Gras
Journal:  BMC Musculoskelet Disord       Date:  2013-02-28       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.