Interseed effects on dose for 125I brachytherapy implants.

A S Meigooni1, J A Meli, R Nath.   

Abstract

Dose calculations in multiseed brachytherapy implants are done by adding the contribution of each individual seed and by assuming that radiation from each seed is unaffected by the presence of the other seeds. To test the validity of this assumption, dose measurements with various configurations of multiseed implants of 125I model 6702 and 125I model 6711 sources were performed. For a linear configuration of three 125I model 6702 seeds at 1-cm separation, with their transverse axes coincident, doses at distances of 3.05 and 5.09 cm from the center along the transverse axis were found to be about 8% lower than the sum of doses from the three individual seeds. However, for three seeds at 1-cm intervals with their longitudinal axes coincident, doses at 3.05 and 5.09 cm distances from the center along the longitudinal axis were found to be about equal to the dose sums from individual seeds. These initial experiments indicated that the magnitude of the interseed effect depends upon the orientation of the seed relative to each other in an implant. To evaluate the importance of this interseed effect for multiseed configurations of 125I model 6702 and 125I model 6711 seeds, dose rates at various distances from a two-plane implant (each plane containing a 3 x 3 array of sources in a 1-cm spacing square grid) were measured in a Solid Water phantom with LiF TLDs. These measurements were carried out in two different planes at different orientations relative to the implant. The average values of the interseed effect at distances ranging from 1 to 7 cm outside the implant were observed to be about the same for 125I model 6702 and model 6711 sources. The mean value of the interseed effect was 6% and the maximum was 12%. On the whole, the interseed effect reduces the dose at the periphery of the iodine implant by 6%.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1584137     DOI: 10.1118/1.596871

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  A dosimetry method for low dose rate brachytherapy by EGS5 combined with regression to reflect source strength shortage.

Authors:  Kenichi Tanaka; Kunihiko Tateoka; Osamu Asanuma; Ken-Ichi Kamo; Kaori Sato; Hiromitsu Takeda; Masaru Takagi; Masato Hareyama; Jun Takada
Journal:  J Radiat Res       Date:  2014-01-20       Impact factor: 2.724

2.  AAPM recommendations on dose prescription and reporting methods for permanent interstitial brachytherapy for prostate cancer: report of Task Group 137.

Authors:  Ravinder Nath; William S Bice; Wayne M Butler; Zhe Chen; Ali S Meigooni; Vrinda Narayana; Mark J Rivard; Yan Yu
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

3.  Fast patient-specific Monte Carlo brachytherapy dose calculations via the correlated sampling variance reduction technique.

Authors:  Andrew Sampson; Yi Le; Jeffrey F Williamson
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

4.  A comparison of the dose distributions between the brachytherapy 125I source models, STM1251 and Oncoseed 6711, in a geometry lacking radiation equilibrium scatter conditions.

Authors:  Kenichi Tanaka; Ken-ichi Kamo; Kunihiko Tateoka; Osamu Asanuma; Kaori Sato; Hiromitsu Takeda; Koh-ichi Sakata; Jun Takada
Journal:  J Radiat Res       Date:  2015-01-24       Impact factor: 2.724

5.  An analytical model to determine interseed attenuation effect in low-dose-rate brachytherapy.

Authors:  Habib Safigholi; Dariush Sardari; Somaye Karimi Jashni; Seied Rabi Mahdavi; Ali S Meigooni
Journal:  J Appl Clin Med Phys       Date:  2013-05-06       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.