Literature DB >> 15839348

Dosimetric effect of collimating jaws for small multileaf collimated fields.

James C L Chow1, Melanie Seguin, Andrew Alexander.   

Abstract

The dosimetric effects from the jaw positioned close to the small field (0.5 x 0.5, 1 x 1, and 2 x 2 cm2) side-edge generated by a single-focused multileaf collimator (MLC) were measured and studied. The measurement is important in intensity modulated radiotherapy (IMRT) because generally the jaw cannot perfectly cover all the leaf-ends in a segment of irregular field. This leads to additional dose contributed by (1) the end surface of the jaw, (2) the leaf-end, and (3) the inter- and intraleaf leakage/transmissions during the dosimetric measurement. Moreover, most of the conventional treatment planning systems ignore these effects in the dose calculation. In this study, measurements were made using a Varian 21 EX linear accelerator with 6 MV photon beam through a MLC containing 120 leaves. Percentage depth dose, beam profile, and output for small fields were measured by varying the jaw at different positions away from the leaf-ends in the field side-edge. Moving the jaw away from the leaf-ends increases the output and penumbra width for the small fields. Such increase is particularly significant when the field size is small (0.5 x 0.5 cm2) and the degree of increase changes quickly when the jaw-end is at about 1-2 cm from the leaf-end. It is suggested that measurements should be carried out in the IMRT commissioning to provide information to physicists in reviewing the treatment planning system's accuracy regarding leaf leakage/transmission and jaw effects.

Mesh:

Year:  2005        PMID: 15839348     DOI: 10.1118/1.1861413

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  13 in total

1.  A planning comparison of dynamic IMRT for different collimator leaf thicknesses with helical tomotherapy and RapidArc for prostate and head and neck tumors.

Authors:  Vesna Jacob; Wolfgang Bayer; Sabrina T Astner; R Busch; Peter Kneschaurek
Journal:  Strahlenther Onkol       Date:  2010-08-30       Impact factor: 3.621

2.  Leakage-Penumbra effect in intensity modulated radiation therapy step-and-shoot dose delivery.

Authors:  Grigor N Grigorov; James Cl Chow
Journal:  World J Radiol       Date:  2016-01-28

3.  On the use of AAA and AcurosXB algorithms for three different stereotactic ablative body radiotherapy (SABR) techniques: Volumetric modulated arc therapy (VMAT), intensity modulated radiation therapy (IMRT) and 3D conformal radiotherapy (3D-CRT).

Authors:  Abdulrahman Tajaldeen; Prabhakar Ramachandran; Salem Alghamdi; Moshi Geso
Journal:  Rep Pract Oncol Radiother       Date:  2019-03-23

4.  Analysis of small field percent depth dose and profiles: Comparison of measurements with various detectors and effects of detector orientation with different jaw settings.

Authors:  Henry Finlay Godson; M Ravikumar; S Sathiyan; K M Ganesh; Y Retna Ponmalar; C Varatharaj
Journal:  J Med Phys       Date:  2016 Jan-Mar

5.  Dosimetric Effect of Jaw Tracking in Volumetric-Modulated Arc Therapy.

Authors:  Sangutid Thongsawad; Chirasak Khamfongkhruea; Chirapha Tannanonta
Journal:  J Med Phys       Date:  2018 Jan-Mar

6.  Rounded leaf end modeling in Pinnacle VMAT treatment planning for fixed jaw linacs.

Authors:  Lori A Young; Fei Yang; Ning Cao; Juergen Meyer
Journal:  J Appl Clin Med Phys       Date:  2016-11-08       Impact factor: 2.102

Review 7.  Influence of the jaw tracking technique on the dose calculation accuracy of small field VMAT plans.

Authors:  Ans C C Swinnen; Michel C Öllers; Erik Roijen; Sebastiaan M Nijsten; Frank Verhaegen
Journal:  J Appl Clin Med Phys       Date:  2017-01-03       Impact factor: 2.102

8.  Dosimetric evaluation of respiratory gated volumetric modulated arc therapy for lung stereotactic body radiation therapy using 3D printing technology.

Authors:  KyoungJun Yoon; Chiyoung Jeong; Sung-Woo Kim; Byungchul Cho; Jungwon Kwak; Su Ssan Kim; Si Yeol Song; Eun Kyung Choi; SeungDo Ahn; Sang-Wook Lee
Journal:  PLoS One       Date:  2018-12-26       Impact factor: 3.240

9.  Dosimetric characteristics of dual-layer multileaf collimation for small-field and intensity-modulated radiation therapy applications.

Authors:  Yaxi Liu; Chengyu Shi; Patricia Tynan; Niko Papanikolaou
Journal:  J Appl Clin Med Phys       Date:  2008-03-31       Impact factor: 2.102

10.  SWIMRT: a graphical user interface using sliding window algorithm to construct a fluence map machine file.

Authors:  James C L Chow; Grigor N Grigorov; Nuri Yazdani
Journal:  J Appl Clin Med Phys       Date:  2006-05-25       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.