Assessment of correlation between computerized tomography values of the bone and cutting torque values at implant placement: a clinical study.

Noriharu Ikumi1, Sadami Tsutsumi.   

Abstract

PURPOSE: The relationship between computerized tomography (CT) values of bone surrounding endosseous implants and the cutting torque values required for self-tapping during implant placement was examined for the purpose of predicting the initial stability (bone quality) during implant placement by presurgical CT scan examinations and determining whether it can be quantified.
MATERIALS AND METHODS: The study sample consisted of 13 subjects with 56 implants. Sites for implant placement were determined based on CT data using implant planning software. The average CT values of the bone surrounding the simulated implants were calculated by the software. Using a stereolithographic drill guide, implants were placed at the locations indicated by the protocol. The cutting torque values required for self-tapping were measured during implant placement. The resulting CT values and cutting torque values were analyzed statistically for correlation.
RESULTS: The correlation was considered significant at a level of .01 or less, and the correlation coefficient was 0.77. DISCUSSION: There was a strong correlation between CT values and cutting torque values in the clinical cases evaluated. These results indicate that it may be possible to predict and quantify initial implant stability and bone quality from presurgical CT diagnosis and implant simulation.
CONCLUSION: Presurgical CT examination may be an effective technique for predicting initial stability of the implant and bone quality.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15839119

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  7 in total

1.  Effect of ultra-low doses, ASIR and MBIR on density and noise levels of MDCT images of dental implant sites.

Authors:  Gerlig Widmann; Reema Al-Shawaf; Peter Schullian; Ra'ed Al-Sadhan; Romed Hörmann; Asma'a A Al-Ekrish
Journal:  Eur Radiol       Date:  2016-09-21       Impact factor: 5.315

2.  The relationship between the bone characters obtained by CBCT and primary stability of the implants.

Authors:  Masahiro Wada; Yasutane Tsuiki; Tohru Suganami; Kazunori Ikebe; Motofumi Sogo; Ikuhisa Okuno; Yoshinobu Maeda
Journal:  Int J Implant Dent       Date:  2015-02-12

Review 3.  Ultralow Dose MSCT Imaging in Dental Implantology.

Authors:  Gerlig Widmann; Asma'a A Al-Ekrish
Journal:  Open Dent J       Date:  2018-01-31

4.  The evaluation of implant stability measured by resonance frequency analysis in different bone types.

Authors:  Naser Sargolzaie; Sarah Samizade; Hamidreza Arab; Habibollah Ghanbari; Leila Khodadadifard; Amin Khajavi
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2019-02-26

5.  Influence of bone density on implant stability parameters and implant success: a retrospective clinical study.

Authors:  Ilser Turkyilmaz; Edwin A McGlumphy
Journal:  BMC Oral Health       Date:  2008-11-24       Impact factor: 2.757

6.  Evaluation of the effects of different surface configurations on stability of miniscrews.

Authors:  Tolga Topcuoglu; A Altuğ Bicakci; M Cihat Avunduk; Z Deniz Sahin Inan
Journal:  ScientificWorldJournal       Date:  2013-07-01

7.  The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis.

Authors:  Tsutomu Sugiura; Kazuhiko Yamamoto; Satoshi Horita; Kazuhiro Murakami; Sadami Tsutsumi; Tadaaki Kirita
Journal:  J Periodontal Implant Sci       Date:  2016-06-28       Impact factor: 2.614

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.