Agreement between peripheral anterior chamber depth evaluation using the van Herick technique and angle width evaluation using the Shaffer system in Japanese.

Kenji Kashiwagi1, Takaharu Tokunaga, Aiko Iwase, Tetsuya Yamamoto, Shigeo Tsukahara.   

Abstract

PURPOSE: To examine the correlation between the van Herick system and the Shaffer system in a large-scale epidemiological survey conducted on healthy Japanese subjects.
METHODS: The van Herick technique was performed on 14,779 subjects aged 40 years and over who participated in an ophthalmic epidemiological survey conducted in Tajimi City, Gifu Prefecture. Eyes classified as grade 1 or 2 according to the van Herick technique were diagnosed as narrow angle eyes, and those eyes were subjected to secondary examination using a gonioscope. In the secondary examination, glaucoma specialists evaluated angle width based on the Shaffer system.
RESULTS: Nine hundred and twenty-three eyes of 505 subjects (108 men and 397 women) were determined to be narrow-angle eyes among the 14 779 subjects surveyed. There were 78 grade 1 eyes and 845 grade 2 eyes. Three hundred and eighty-three subjects (75.8%) underwent gonioscopic examination, and 426 eyes (65.9%) had an angle as narrow as or narrower than Shaffer grade 2. Among the 51 eyes evaluated as van Herick grade 1, 44 (86.3%) had an angle an narrow as or narrower than Shaffer grade 2, while among the 595 eyes evaluated as van Herick grade 2,382 (64.2%) had an angle as narrow as or narrower than Shaffer grade 2.
CONCLUSIONS: The van Herick technique closely coincided with the Shaffer system and was found to have a potential for use as a simple method for evaluating narrow-angle eyes in Japanese.

Entities:  

Mesh:

Year:  2005        PMID: 15838730     DOI: 10.1007/s10384-004-0169-5

Source DB:  PubMed          Journal:  Jpn J Ophthalmol        ISSN: 0021-5155            Impact factor:   2.447


  3 in total

1.  Comparison of techniques for measuring anterior chamber depth: Orbscan imaging, Smith's technique, and van Herick's method.

Authors:  Frank Eperjesi; Claire Holden
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-09-10       Impact factor: 3.117

Review 2.  Anterior Chamber Angle Assessment Techniques: A Review.

Authors:  Ivano Riva; Eleonora Micheletti; Francesco Oddone; Carlo Bruttini; Silvia Montescani; Giovanni De Angelis; Luigi Rovati; Robert N Weinreb; Luciano Quaranta
Journal:  J Clin Med       Date:  2020-11-25       Impact factor: 4.241

3.  Ultrasound biomicroscopic findings of the iridocorneal angle in live healthy and glaucomatous dogs.

Authors:  Takashi Hasegawa; Manabu Kawata; Mitsuharu Ota
Journal:  J Vet Med Sci       Date:  2015-07-24       Impact factor: 1.267