Intermittent pneumatic foot compression can activate blood fibrinolysis without changes in blood coagulability and platelet activation.

S Kohro1, M Yamakage, K Sato, J-I Sato, A Namiki.   

Abstract

BACKGROUND: Intermittent pneumatic foot compression (IPC) is a useful technique for prophylaxis of peri-operative venous thromboembolism. The aim of this study was to determine the effect of IPC on blood coagulation/fibrinolysis and platelet function using a blood viscometer (Sonoclot) and a platelet aggregation monitor (WBA analyzer(TM)), respectively. Using the same blood samples, serum levels of tissue-type plasminogen activator (t-PA), thrombomodulin (TM) and activated protein C (APC) were also measured.
METHODS: The soles and legs of each subject (n = 8) were compressed for 3 s (130 mmHg) at a 0.3-Hz interval using an IPC device. Parameters were measured 2 min before and at the end of 60-min compression.
RESULTS: Parameters of the Sonoclot time-to-peak were shortened and clot retraction rate was increased significantly by IPC, whereas the other parameters did not change. These results indicate that IPC can activate blood fibrinolysis but not coagulability. A parameter of the WBA analyzer PATI (platelet aggregatory threshold index) did not change, indicating that IPC cannot activate platelet function per se. The concentration of t-PA decreased slightly but significantly. A decrease in the concentration of t-PA can lead to activation of fibrinolysis. Other humoral parameters did not change, indicating that IPC has no effect on endothelial function. Although neither blood coagulability nor platelet function were affected by IPC, fibrinolytic activity increased slightly, probably by activation of t-PA function.
CONCLUSION: IPC is useful for prophylaxis for thromboembolism by activation of blood fibrinolysis as well as inhibition of blood stasis.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15836680     DOI: 10.1111/j.1399-6576.2005.00661.x

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  5 in total

Review 1.  Causes of death among persons who survive an acute ischemic stroke.

Authors:  Shuai Zhang; Wen-Bin He; Nai-Hong Chen
Journal:  Curr Neurol Neurosci Rep       Date:  2014-08       Impact factor: 5.081

Review 2.  Different types of intermittent pneumatic compression devices for preventing venous thromboembolism in patients after total hip replacement.

Authors:  Jin Min Zhao; Mao Lin He; Zeng Ming Xiao; Ting Song Li; Hao Wu; Hua Jiang
Journal:  Cochrane Database Syst Rev       Date:  2014-12-22

3.  Intense Triceps Surae Contraction Increases Lower Extremity Venous Blood Flow.

Authors:  Kouji Tsuda; Naonobu Takahira; Miki Sakamoto; Ato Shinkai; Kazuki Kaji; Jun Kitagawa
Journal:  Prog Rehabil Med       Date:  2017-07-05

4.  Hemodynamic analysis of intermittent pneumatic compression combined with hyperthermia after total hip arthroplasty: an experiment on male rabbits.

Authors:  Siping Zhang; Pengcheng Ma; Aikeremujiang Muheremu; Rongxin Sun; Hao Chai; Kan Jiang
Journal:  Am J Transl Res       Date:  2022-05-15       Impact factor: 3.940

Review 5.  Electrical muscle stimulation in thomboprophylaxis: review and a derived hypothesis about thrombogenesis-the 4th factor.

Authors:  Christos Stefanou
Journal:  Springerplus       Date:  2016-06-24