Literature DB >> 15835138

Adsorption of trinitrotoluene on uncoated silicon microcantilever surfaces.

L A Pinnaduwage1, D Yi, F Tian, T Thundat, R T Lareau.   

Abstract

We measured the adsorption characteristics of trinitrotoluene (TNT) on piezoresistive silicon microcantilever surfaces under ambient air using a well-characterized TNT vapor generator. This allowed us to quantify the adsorption parameters and to estimate the sticking coefficient. The sticking coefficient initially increases with TNT exposure time and then levels off around 0.3. Atomic force microscopy images of silicon surfaces exposed to TNT revealed "island" formation of the adsorbate on the silicon surface. At low exposure times, mainly the number density of islands increased with exposure time; at longer exposure times, the size (in particular, height) of the islands grew, corresponding to the higher sticking coefficients. These observations can be qualitatively explained via the difference between TNT-surface and TNT-TNT interactions mediated by water molecules.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15835138     DOI: 10.1021/la035658f

Source DB:  PubMed          Journal:  Langmuir        ISSN: 0743-7463            Impact factor:   3.882


  5 in total

1.  Quantitative detection of trace explosive vapors by programmed temperature desorption gas chromatography-electron capture detector.

Authors:  Christopher R Field; Adam Lubrano; Morgan Woytowitz; Braden C Giordano; Susan L Rose-Pehrsson
Journal:  J Vis Exp       Date:  2014-07-25       Impact factor: 1.355

2.  A nanosensor for TNT detection based on molecularly imprinted polymers and surface enhanced Raman scattering.

Authors:  Ellen L Holthoff; Dimitra N Stratis-Cullum; Mikella E Hankus
Journal:  Sensors (Basel)       Date:  2011-03-01       Impact factor: 3.576

3.  Cu(OH)₂ and CuO Nanorod Synthesis on Piezoresistive Cantilevers for the Selective Detection of Nitrogen Dioxide.

Authors:  Laurent Schlur; Manuel Hofer; Ahmad Ahmad; Karine Bonnot; Mathias Holz; Denis Spitzer
Journal:  Sensors (Basel)       Date:  2018-04-05       Impact factor: 3.576

4.  A self-sensing piezoelectric microcantilever biosensor for detection of ultrasmall adsorbed masses: theory and experiments.

Authors:  Samira Faegh; Nader Jalili; Srinivas Sridhar
Journal:  Sensors (Basel)       Date:  2013-05-10       Impact factor: 3.576

5.  Sensitivity comparison of vapor trace detection of explosives based on chemo-mechanical sensing with optical detection and capacitive sensing with electronic detection.

Authors:  Drago Strle; Bogdan Štefane; Erik Zupanič; Mario Trifkovič; Marijan Maček; Gregor Jakša; Ivan Kvasič; Igor Muševič
Journal:  Sensors (Basel)       Date:  2014-06-27       Impact factor: 3.576

  5 in total