Literature DB >> 15832575

[Assessment of precision and accuracy of digital surface photogrammetry with the DSP 400 system].

M Krimmel1, S Kluba, K Dietz, S Reinert.   

Abstract

The objective of the present study was to evaluate the precision and accuracy of facial anthropometric measurements obtained through digital 3-D surface photogrammetry with the DSP 400 system in comparison to traditional 2-D photogrammetry. Fifty plaster casts of cleft infants were imaged and 21 standard anthropometric measurements were obtained. For precision assessment the measurements were performed twice in a subsample. Accuracy was determined by comparison of direct measurements and indirect 2-D and 3-D image measurements. Precision of digital surface photogrammetry was almost as good as direct anthropometry and clearly better than 2-D photogrammetry. Measurements derived from 3-D images showed better congruence to direct measurements than from 2-D photos. Digital surface photogrammetry with the DSP 400 system is sufficiently precise and accurate for craniofacial anthropometric examinations.

Entities:  

Mesh:

Year:  2005        PMID: 15832575     DOI: 10.1515/BMT.2005.008

Source DB:  PubMed          Journal:  Biomed Tech (Berl)        ISSN: 0013-5585            Impact factor:   1.411


  5 in total

1.  Implementing a superimposition and measurement model for 3D sagittal analysis of therapy-induced changes in facial soft tissue: a pilot study.

Authors:  Claudia Sade Hoefert; Margit Bacher; Tina Herberts; Michael Krimmel; Siegmar Reinert; Sebastian Hoefert; Gernot Göz
Journal:  J Orofac Orthop       Date:  2010-05-26       Impact factor: 1.938

2.  3D soft tissue changes in facial morphology in patients with cleft lip and palate and class III mal occlusion under therapy with rapid maxillary expansion and delaire facemask.

Authors:  Claudia Sade Hoefert; Margit Bacher; Tina Herberts; Michael Krimmel; Siegmar Reinert; Gernot Göz
Journal:  J Orofac Orthop       Date:  2010-04-01       Impact factor: 1.938

3.  Validation of a low-cost portable 3-dimensional face scanner.

Authors:  Catherine Liu; Andreas Artopoulos
Journal:  Imaging Sci Dent       Date:  2019-03-25

4.  Standardized Three-Dimensional Lateral Distraction Test: Its Reliability to Assess Medial Canthal Tendon Laxity.

Authors:  Xiaoyi Hou; Alexander C Rokohl; Yongwei Guo; Ludwig M Heindl; Marius M Meinke; Jinhua Liu; Senmao Li; Wanlin Fan; Ming Lin; Renbing Jia
Journal:  Aesthetic Plast Surg       Date:  2021-07-07       Impact factor: 2.708

5.  Development of a Three-Dimensional Hand Model Using Three-Dimensional Stereophotogrammetry: Assessment of Image Reproducibility.

Authors:  Inge A Hoevenaren; J Meulstee; E Krikken; S J Bergé; D J O Ulrich; Thomas J J Maal
Journal:  PLoS One       Date:  2015-09-14       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.