Literature DB >> 15832160

Two-stage flexor tendon reconstruction in zone 2 of the hand in children.

Nickolaos A Darlis1, Alexandros E Beris, Anastasios V Korompilias, Marios D Vekris, Gregory I Mitsionis, Panayiotis N Soucacos.   

Abstract

Two-stage flexor tendon reconstruction (Hunter) is indicated in children with extensive adhesions in zone 2 of the hand, with some reservations concerning the patient's age and cooperation. Nine children (mean age 6.9 years) were treated with the modified Paneva-Holevich technique, which has advantages over the classic Hunter reconstructions. It involves an intrasynovial graft (FDS of the injured finger) that is anatomically stable and morphologically more appropriate compared with free grafts. The size of the silicone rod is precisely assessed in the first stage, the proximal tenorrhaphy has healed by the time the second stage is performed, and donor site morbidity is minimized. After a mean follow-up of 40.1 months, the mean total active motion was 196 degrees, and eight patients achieved a good or excellent result according to the Buck-Gramcko and the revised Strickland scale. Staged flexor tendon reconstruction is technically feasible even in very young children. Results in children are comparable to those achieved in adults.

Entities:  

Mesh:

Year:  2005        PMID: 15832160     DOI: 10.1097/01.bpo.0000152939.28413.a2

Source DB:  PubMed          Journal:  J Pediatr Orthop        ISSN: 0271-6798            Impact factor:   2.324


  4 in total

1.  [Flexor tendon transplantation].

Authors:  M F Langer; B Wieskötter; K Herrmann; S Oeckenpöhler
Journal:  Orthopade       Date:  2015-10       Impact factor: 1.087

Review 2.  [Secondary reconstruction of flexor tendons].

Authors:  Martin Franz Langer; Britta Wieskötter; Simon Oeckenpöhler; Frank Unglaub; Christian Spies; Jörg G Grünert
Journal:  Unfallchirurg       Date:  2020-02       Impact factor: 1.000

3.  Two-stage reconstruction for flexor tendon injuries in zone II using a silicone rod and pedicled sublimis tendon graft.

Authors:  Mohammed Heshmat Abdul-Kader; Mahmound A M Amin
Journal:  Indian J Plast Surg       Date:  2010-01

4.  Silicone Foley's catheter as an effective alternative to Hunter's rod in staged flexor tendon reconstruction of the hand.

Authors:  Tawheed Ahmad; Sheikh Adil Bashir; Mohammad Inam Zaroo; Adil Hafeez Wani; Saima Rashid; Summaira Jan
Journal:  Indian J Plast Surg       Date:  2016 Sep-Dec
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.