Abstract
A novel method for the determination of L-carnitine in food supplement formulations was developed and validated, using ion-pair chromatography with indirect conductimetric detection. The chromatographic method was based on a non-polar (C18) column and an aqueous octanesulfonate (0.64 mM) eluent, acidified with trifluoroacetic acid (5.2 mM). The retention time was 5.4 min and the asymmetry factor 0.65. A linear calibration curve from 10 to 1000 microg/ml (r= 0.99998), with a detection limit of 2.7 microg/ml (25 microl injection volume), a repeatability %RSD of 0.8 (40 microg/ml, n = 5) and reproducibility %RSD of 2.6 were achieved. The proposed method was applied for the determination of carnitine in oral solutions and capsules. No interference from excipients was found and the only pretreatment step required was the appropriate dilution with the mobile phase. Recovery from spiked samples was ranged from 97.7 to 99.7% with a precision (%RSD, n = 3) of 0.01-2.1%.Entities:
Mesh:
Substances:
Year: 2005 PMID: 15830947 DOI: 10.1016/j.chroma.2005.02.021