| Literature DB >> 1583016 |
H H Savelberg1, J G Kooloos, R Huiskes, J M Kauer.
Abstract
In the present study the stiffness of the superficial ligaments of 14 human cadaver wrist joints have been determined. In these experiments the tested, fresh-frozen carpal joints are divided into a number of bone-ligament-bone complexes, which are loaded in a tensile testing machine at a rate of 66% of the ligaments' initial length per second to a maximal strain of 15%. From the force-elongation curves and ligament dimensions the tangent moduli for the ligament-bone strips are derived. The results show that, with regard to the tangent modulus, there is not a clear differentiation among ligament strips. Only the dorsal radiotriquetrum ligament (RTD) and the palmar radiocapitate ligament (RCP) appear to consist of a material of a relatively high tangent modulus, about 93 and 83 MPa, respectively. The other seven ligaments tested have similar tangent moduli, ranging from 25 to about 50 MPa.Entities:
Mesh:
Year: 1992 PMID: 1583016 DOI: 10.1016/0021-9290(92)90256-z
Source DB: PubMed Journal: J Biomech ISSN: 0021-9290 Impact factor: 2.712