A computer-based biomechanical analysis of the three-dimensional motion of cementless hip prostheses.

J L Gilbert1, R S Bloomfeld, E P Lautenschlager, R L Wixson.   

Abstract

A computer-based mathematical technique was developed to measure and completely describe the migration and micromotion of a femoral hip prosthesis relative to the femur. This technique utilized the mechanics of rigid-body motion analysis and apparatus of seven linear displacement transducers to measure and describe the complete three-dimensional motion of the prosthesis during cyclic loading. Computer acquisition of the data and custom analysis software allowed one to calculate the magnitude and direction of the motion of any point of interest on the prostheses from information about the motion of two points on the device. The data were also used to replay the tests using a computer animation technique, which allowed a magnified view of the three-dimensional motion of the prosthesis. This paper describes the mathematical development of the rigid-body motion analysis, the experimental method and apparatus for data collection, the technique used to animate the motion, the sources of error and the effect of the assumptions (rigid bodies) on the results. Selected results of individual test runs of uncemented and cemented prostheses are presented to demonstrate the efficacy of the method. The combined effect of the vibration and electrical noise resulted in a resolution of the system of about 3-5 microns motion for each transducer. Deformation effects appear to contribute about 3-15 microns to the measurement error. This measurement and analysis technique is a very sensitive and powerful means of assessing the effects of different design parameters on the migration and micromotion of total joint prostheses and can be applied to any other case (knee, dental implant) where three-dimensional relative motion between two bodies is important.

Mesh:

Substances:

Year:  1992        PMID: 1583012     DOI: 10.1016/0021-9290(92)90252-v

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  3 in total

1.  Effects of surface microtopography on the assembly of the osteoclast resorption apparatus.

Authors:  Dafna Geblinger; Christian Zink; Nicholas D Spencer; Lia Addadi; Benjamin Geiger
Journal:  J R Soc Interface       Date:  2011-11-16       Impact factor: 4.118

2.  Stability of fused versus nonfused THA femoral impaction grafts.

Authors:  Anneliese D Heiner; John J Callaghan; Thomas D Brown
Journal:  J Orthop Res       Date:  2007-03       Impact factor: 3.494

3.  Efficacy of computer-assisted, 3D motion-capture toothbrushing instruction.

Authors:  Kee-Deog Kim; Jin-Sun Jeong; Hae Na Lee; Yu Gu; Kyeong-Seop Kim; Jeong-Whan Lee; Wonse Park
Journal:  Clin Oral Investig       Date:  2014-11-14       Impact factor: 3.573

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.