Literature DB >> 15829554

Fraction of the positive 218Po and 214Pb clusters in indoor air.

J Porstendörfer1, P Pagelkopf, M Gründel.   

Abstract

The fraction of the positively charged unattached radon decay products, 218Po and 214Pb in indoor air was determined by model calculations. The results of the calculations were confirmed by measurements in a test chamber (volume: 8 m3). The fraction of both radionuclides depends on the attachment parameter (S(1)) and the neutralisation rate (nu) in room air. The total removal parameter S1 = lambda1 + v + q(f) + X = lambda1 C1f/C0 considers the attachment rate to aerosol particles (X), plate-out rate to room surfaces (q(f)) and the ventilation rate (nu) (lambda1: decay constant of 218Po). The S1-value of room can be determined by measurement of the concentration of the unattached 218Po clusters (C1f) and radon (C0). The neutralisation rate (nu) in environmental air depends mainly on the ion production rate. The influence of the relative humidity in the range 30-95% (temperature: 20 degrees C) is negligible. In addition, equal neutralisation rates for 218Po and 214Pb could be derived. In room air with ion production rates between 5 and 500 nC kg(-1) h(-1) mainly generated by the alpha emitters of radon, thoron and their short-lived decay products, the fractions for positive 218Po clusters vary between 55 and 17% and for 214Pb clusters between 53 and 14%. For a typical average concentration of radon (50 Bq m(-3)) and thoron (10 Bq m(-3)) in homes, 48% of 218Po clusters and 45% of 214Pb clusters are positively charged.

Mesh:

Substances:

Year:  2005        PMID: 15829554     DOI: 10.1093/rpd/nch465

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  3 in total

Review 1.  Does protracted radon exposure play a role in the development of dementia?

Authors:  Yijia Zhang; Liping Lu; Cheng Chen; R William Field; Mary D'Alton; Ka Kahe
Journal:  Environ Res       Date:  2022-02-19       Impact factor: 8.431

2.  Estimation of Radiological Dose From Progeny of 222Rn and 220Rn Using DTPS/DRPS and Wire-Mesh-Capped Progeny Sensors.

Authors:  Rohit Mehra; Rajan Jakhu; Pargin Bangotra; Harish Mohan Mittal
Journal:  Dose Response       Date:  2016-12-08       Impact factor: 2.658

3.  Quantification of an alpha flux based radiological dose from seasonal exposure to 222Rn, 220Rn and their different EEC species.

Authors:  Pargin Bangotra; Rohit Mehra; Rajan Jakhu; Pragya Pandit; Mukesh Prasad
Journal:  Sci Rep       Date:  2019-02-21       Impact factor: 4.379

  3 in total