Literature DB >> 15828796

SIMPLISMA and ALS applied to two-way nonlinear wavelet compressed ion mobility spectra of chemical warfare agent simulants.

Libo Cao1, Peter de B Harrington, Jundong Liu.   

Abstract

Ion mobility spectrometry is a rapid scanning measurement method for which compression methods that facilitate the handling of large collections of data are beneficial. Peak distortion in reconstructed ion mobility spectra from linear wavelet compression is problematic in that artifact peaks may cause false positive alarms. Peak shifting also may cause false alarms if target peaks shift out of or interfering peaks shift into detection windows. Nonlinear wavelet compression (NLWC) preserves peak shape and can lessen the degree of distortion, shifting, and artifact peaks in the reconstructed spectra. NLWC was applied to achieve high compression and fidelity in the reconstructed spectra. Another benefit is that NLWC improves signal-to-noise ratios and thus the models built from compressed data are improved. By compressing both the drift time order and the spectrum acquisition order, greater compressions maybe achieved. A two-way nonlinear wavelet compression method that incorporates alternating least squares (2W-NLWC-ALS) algorithm was devised by applying ALS to partially reconstructed wavelet coefficients generated from two-way NLWC. The number of components in a data set can be determined automatically using ASIMPLISMA. The smaller ALS models are saved as the final compressed data and can be used to reconstruct the entire data set efficiently without maintaining the compressed wavelet coefficient matrix of the original data set. The 2W-NLWC-ALS algorithm provides greater compression ratios compared to regular wavelet compression and interpretable models. Using this method, large volumes of data can be acquired and easily evaluated through a simple compressed model. A compression ratio of 510 ppm, root-mean-square error (E(RMS)) of 6.3 mV (full-scale signal is usually 1 V or larger), and relative root-mean-square error (RE(RMS)) of 1.62% were achieved for data sets collected by CAM. A compression ratio of 46 ppm, E(RMS) of 9.2 mV, and RE(RMS) of 0.42% were achieved for data sets collected with an ITEMISER instrument. The 2W-NLWC-ALS algorithm is an efficient compression method that provides the benefits of a simple model.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15828796     DOI: 10.1021/ac0486286

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  1 in total

1.  An improved independent component analysis model for 3D chromatogram separation and its solution by multi-areas genetic algorithm.

Authors:  Lizhi Cui; Josiah Poon; Simon K Poon; Hao Chen; Junbin Gao; Paul Kwan; Kei Fan; Zhihao Ling
Journal:  BMC Bioinformatics       Date:  2014-11-06       Impact factor: 3.169

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.