Literature DB >> 15819671

Clinical significance of bacteriologic screening in platelet concentrates.

P A W te Boekhorst1, E A M Beckers, M C Vos, H Vermeij, D J van Rhenen.   

Abstract

BACKGROUND: Despite routine bacterial screening with a bacterial culturing system (BacT/ALERT, bioMerieux) of platelet (PLT) concentrates, two cases of life-threatening sepsis attributed to transfused PLT products contaminated with Bacillus cereus were reported to the regional hemovigilance office in the southwest region of the Netherlands. These reports necessitated a retrospective evaluation of the currently applied bacteriologic screening program. STUDY DESIGN AND METHODS: Bacteriologic screening of all PLT concentrates on production was introduced in October 2001. Aliquots (5-10 mL) of pooled PLT concentrates in additive solution were taken for cultures with the BacT/ALERT system 14 to 24 hours after donation. The total culturing period was 7 days and in case of positive signals, identification cultures were taken from the culture bottles. The results of the bacterial screening, identification, and clinical significance of possibly contaminated pooled PLT concentrates were evaluated retrospectively over a 2-year period.
RESULTS: In this period, a total of 28,104 pooled PLT concentrates were produced. Positive bacterial screening was found in 0.72 percent (n = 203). Of these, in 184 pooled PLT concentrates bacteria were cultured and identified, and in the remaining 19 (9.4%) identification cultures were negative. Before a positive screening was found, 113 PLT concentrates had already been transfused without the occurrence of clinical significant transfusion reactions.
CONCLUSION: Bacterial contamination of pooled PLT concentrates was not related to clinically significant transfusion reactions. Despite negative screening for bacterial contamination, life-threatening transfusion-transmitted infections by contaminated PLT products can still occur. Other strategies should be applied to guarantee a higher degree of bacteriologic safety.

Entities:  

Mesh:

Year:  2005        PMID: 15819671     DOI: 10.1111/j.0041-1132.2005.04270.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  8 in total

1.  Effect of Safety Measures on Bacterial Contamination Rates of Blood Components in Germany.

Authors:  Gabriele Walther-Wenke; Walter Däubener; Margarethe Heiden; Jochen Hoch; Britt Hornei; Peter Volkers; Carl Heinz Wirsing von König
Journal:  Transfus Med Hemother       Date:  2011-07-11       Impact factor: 3.747

2.  10 Years Experience with Bacterial Screening of Platelet Concentrates in the Netherlands.

Authors:  Dirk de Korte
Journal:  Transfus Med Hemother       Date:  2011-07-08       Impact factor: 3.747

3.  Direct detection of the bacterial stress response in intact samples of platelets by differential impedance.

Authors:  Ronald Rieder; Zhihui Zhao; Aphakorn Nittayajarn; Boris Zavizion
Journal:  Transfusion       Date:  2010-10-26       Impact factor: 3.157

4.  Implementation of Bacterial Detection Methods into Blood Donor Screening - Overview of Different Technologies.

Authors:  Michael Schmidt; Walid Sireis; Erhard Seifried
Journal:  Transfus Med Hemother       Date:  2011-07-07       Impact factor: 3.747

5.  Reactions Induced by Platelet Transfusions.

Authors:  Volker Kiefel
Journal:  Transfus Med Hemother       Date:  2008-09-16       Impact factor: 3.747

6.  Bacterial screening of platelet concentrates on day 2 and 3 with flow cytometry: the optimal sampling time point?

Authors:  Tanja Vollmer; Volkmar Schottstedt; Juergen Bux; Gabriele Walther-Wenke; Cornelius Knabbe; Jens Dreier
Journal:  Blood Transfus       Date:  2014-01-02       Impact factor: 3.443

7.  The Pan Genera Detection immunoassay: a novel point-of-issue method for detection of bacterial contamination in platelet concentrates.

Authors:  Tanja Vollmer; Dennis Hinse; Knut Kleesiek; Jens Dreier
Journal:  J Clin Microbiol       Date:  2010-08-11       Impact factor: 5.948

8.  Nationwide Implementation of Pathogen Inactivation for All Platelet Concentrates in Switzerland.

Authors:  Markus Jutzi; Behrouz Mansouri Taleghani; Morven Rueesch; Lorenz Amsler; Andreas Buser
Journal:  Transfus Med Hemother       Date:  2018-05-23       Impact factor: 3.747

  8 in total