Literature DB >> 15817065

A procedure to determine the correct thickness of an object with confocal microscopy in case of refractive index mismatch.

L C Kuypers1, W F Decraemer, J J J Dirckx, J-P Timmermans.   

Abstract

A difference in refractive index (n) between immersion medium and specimen results in increasing loss of intensity and resolution with increasing focal depth and in an incorrect axial scaling in images of a confocal microscope. Axial thickness measurements of an object on such images are therefore not exact. The present paper describes a simple procedure to determine the correct axial thickness of an object with confocal fluorescence microscopy. We study this procedure for a specimen that has a higher refractive index than the immersion medium and with a thickness up to 100 microm. The measuring method was experimentally tested by comparing the thickness of polymer layers measured on axial images of a confocal microscope in case of a water-polymer mismatch to reference values obtained from an independent technique, i.e. scanning electron microscopy. The case when the specimen has a lower refractive index than the immersion medium is also shown by way of illustration. Measured thickness data of a water layer and an oil layer with the same actual thickness were obtained using an oil-immersion objective lens with confocal microscopy. Good agreement between theory and experiment was found in both cases, consolidating our method.

Entities:  

Year:  2005        PMID: 15817065     DOI: 10.1111/j.1365-2818.2005.01457.x

Source DB:  PubMed          Journal:  J Microsc        ISSN: 0022-2720            Impact factor:   1.758


  12 in total

1.  Moving Cell Boundaries Drive Nuclear Shaping during Cell Spreading.

Authors:  Yuan Li; David Lovett; Qiao Zhang; Srujana Neelam; Ram Anirudh Kuchibhotla; Ruijun Zhu; Gregg G Gundersen; Tanmay P Lele; Richard B Dickinson
Journal:  Biophys J       Date:  2015-08-18       Impact factor: 4.033

2.  Thickness distribution of fresh eardrums of cat obtained with confocal microscopy.

Authors:  Liesbeth C Kuypers; W F Decraemer; J J J Dirckx; J-P Timmermans
Journal:  J Assoc Res Otolaryngol       Date:  2005-09

3.  High-resolution solid modeling of biological samples imaged with 3D fluorescence microscopy.

Authors:  Michael C Ferko; Brian W Patterson; Peter J Butler
Journal:  Microsc Res Tech       Date:  2006-08       Impact factor: 2.769

Review 4.  Calcific aortic valve stenosis: methods, models, and mechanisms.

Authors:  Jordan D Miller; Robert M Weiss; Donald D Heistad
Journal:  Circ Res       Date:  2011-05-27       Impact factor: 17.367

5.  Addressing systematic errors in axial distance measurements in single-emitter localization microscopy.

Authors:  Petar N Petrov; W E Moerner
Journal:  Opt Express       Date:  2020-06-22       Impact factor: 3.894

6.  Modulation of Nuclear Shape by Substrate Rigidity.

Authors:  David B Lovett; Nandini Shekhar; Jeffrey A Nickerson; Kyle J Roux; Tanmay P Lele
Journal:  Cell Mol Bioeng       Date:  2013-06-01       Impact factor: 2.321

7.  Simple Experimental Methods for Determining the Apparent Focal Shift in a Microscope System.

Authors:  Benjamin P Bratton; Joshua W Shaevitz
Journal:  PLoS One       Date:  2015-08-13       Impact factor: 3.240

8.  The mammalian LINC complex regulates genome transcriptional responses to substrate rigidity.

Authors:  Samer G Alam; Qiao Zhang; Nripesh Prasad; Yuan Li; Srikar Chamala; Ram Kuchibhotla; Birendra Kc; Varun Aggarwal; Shristi Shrestha; Angela L Jones; Shawn E Levy; Kyle J Roux; Jeffrey A Nickerson; Tanmay P Lele
Journal:  Sci Rep       Date:  2016-12-01       Impact factor: 4.379

9.  A Rapid Detection Method for Morphological Characteristics of Biological Cells Based on Phase Imaging.

Authors:  Wen-Bo Tang; Ying Ji; Ming-Ming Zhang; Zhi-Ya Chen; Yuan-Yuan Xu; Ya-Wei Wang
Journal:  Biomed Res Int       Date:  2018-04-11       Impact factor: 3.411

10.  A method for direct imaging of x-z cross-sections of fluorescent samples.

Authors:  A Katiyar; J D Antani; B P McKee; R Gupta; P P Lele; T P Lele
Journal:  J Microsc       Date:  2020-10-19       Impact factor: 1.758

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.