Intraoperative insertion torque of lumbar pedicle screw and postoperative radiographic evaluation: short-term observation.

Koichi Mizuno1, Kenichi Shinomiya, Osamu Nakai, Shigeo Shindo, Kazuyuki Otani.   

Abstract

The correlation between the insertion torque of a lumbar pedicle screw and the mechanical stability of the screw in the bone has been mentioned in in vitro studies. The purpose of this study was to confirm the factors affecting the insertion torque of such screws in vivo. Also, the contribution of insertion torque to the initial stability of the fusion area was to be analyzed in vivo. A series of 23 cases representing 50 lumbar vertebrae were included in this study, in which we examined bone mineral density using quantitative computed tomography (CT) prior to operation. Two screw shapes were utilized, with the insertion torque for each screw measured at two points in time. The correlation between insertion torque and mineral density was investigated. Screw positions were confirmed on postoperative CT scans, and the effect of the screw thread cutting into the cortex bone was investigated. Radiographic changes at three points during a period of 3 months were also measured, and we then evaluated the interrelations between these changes and insertion torque. Furthermore, the relation between insertion torque and instability at 3 months was investigated. Correlations of insertion torque and bone mineral density depended on screw shape. There was no correlation found with mineral density in the case of cylindrical screws. Insertion torque was not affected by the screw thread cutting into the cortex of bone. As for postoperative alignment changes, no definitive trends could be ascertained, and no interrelations with torque and alignment changes were observed. There is a possibility that insertion torque was related to early-stage stability, but no statistical relation could be determined.

Mesh:

Year:  2005        PMID: 15815860     DOI: 10.1007/s00776-004-0873-5

Source DB:  PubMed          Journal:  J Orthop Sci        ISSN: 0949-2658            Impact factor:   1.601


  4 in total

1.  Insertion torque is not a good predictor of pedicle screw loosening after spinal instrumentation: a prospective study in 8 patients.

Authors:  Bengt Sandén; Claes Olerud; Sune Larsson; Yohan Robinson
Journal:  Patient Saf Surg       Date:  2010-09-03

2.  Mechanical torque measurement in the proximal femur correlates to failure load and bone mineral density ex vivo.

Authors:  Stefan Grote; Tatjana Noeldeke; Michael Blauth; Wolf Mutschler; Dominik Bürklein
Journal:  Orthop Rev (Pavia)       Date:  2013-06-24

3.  Evaluating Pedicle-Screw Instrumentation Using Decision-Tree Analysis Based on Pullout Strength.

Authors:  Vicky Varghese; Venkatesh Krishnan; Gurunathan Saravana Kumar
Journal:  Asian Spine J       Date:  2018-07-27

4.  Risk Factor Analysis of Facet Fusion Following Cervical Lateral Mass Screw Fixation with a Minimum 1-Year Follow-up: Assessment of Maximal Insertional Screw Torque and Incidence of Loosening.

Authors:  Ryo Kanematsu; Junya Hanakita; Toshiyuki Takahashi; Manabu Minami; Tomoo Inoue; Fumiaki Honda
Journal:  Neurol Med Chir (Tokyo)       Date:  2020-11-18       Impact factor: 1.742

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.