An outbreak of Pontiac fever with respiratory distress among workers performing high-pressure cleaning at a sugar-beet processing plant.

Mei Lin Castor1, Elizabeth A Wagstrom, Richard N Danila, Kirk E Smith, Timothy S Naimi, John M Besser, Keith A Peacock, Billie A Juni, John M Hunt, Joanne M Bartkus, Steven R Kirkhorn, Ruth Lynfield.   

Abstract

BACKGROUND: In August 2000, the Minnesota Department of Health was notified of and investigated an outbreak of febrile respiratory illness among workers at a sugar-beet processing plant.
METHODS: A case was defined as fever and respiratory symptoms occurring in a worker at the sugar-beet plant on or after 31 July 2000. Case patients were interviewed, medical and work records were reviewed, and clinical samples were obtained. The plant was inspected, and environmental samples were collected.
RESULTS: Fourteen of 15 case patients performed high-pressure water cleaning in the confined space of an evaporator vessel. Symptoms included fever and chills (100%), chest tightness (93%), cough (80%), and shortness of breath (73%). In case patients, median temperature was 39.4 degrees C, median oxygen saturation was 93%, and median white blood cell count was 12x10(3) cells/ mu L. Four (29%) of 14 case patients showed evidence of Legionella pneumophila exposure, according to serologic testing. Water sources contained up to 10(5) cfu/mL of L. pneumophila and 22,200 endotoxin units/mL.
CONCLUSIONS: Outbreak features were consistent with Pontiac fever. Respiratory symptoms, which are atypical for Pontiac fever, could be attributed to a high exposure dose of L. pneumophila from confined-space aerosolization or to endotoxin exposure. This outbreak demonstrates the potential occupational hazards for those performing high-pressure cleaning in confined spaces.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15809913     DOI: 10.1086/428776

Source DB:  PubMed          Journal:  J Infect Dis        ISSN: 0022-1899            Impact factor:   5.226


  3 in total

Review 1.  Current and emerging Legionella diagnostics for laboratory and outbreak investigations.

Authors:  Jeffrey W Mercante; Jonas M Winchell
Journal:  Clin Microbiol Rev       Date:  2015-01       Impact factor: 26.132

2.  Pontiac fever: an operational definition for epidemiological studies.

Authors:  Paul Tossa; Magali Deloge-Abarkan; Denis Zmirou-Navier; Philippe Hartemann; Laurence Mathieu
Journal:  BMC Public Health       Date:  2006-04-28       Impact factor: 3.295

Review 3.  Epidemiology and Ecology of Opportunistic Premise Plumbing Pathogens: Legionella pneumophila, Mycobacterium avium, and Pseudomonas aeruginosa.

Authors:  Joseph O Falkinham; Elizabeth D Hilborn; Matthew J Arduino; Amy Pruden; Marc A Edwards
Journal:  Environ Health Perspect       Date:  2015-03-20       Impact factor: 9.031

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.