Literature DB >> 15808256

Effect of microkeratome suction during LASIK on ocular structures.

Alireza Mirshahi1, Thomas Kohnen.   

Abstract

PURPOSE: To study the effect of microkeratome suction on ocular structures during LASIK.
DESIGN: Observational, prospective case series. PARTICIPANTS: Twenty-one eyes of 11 patients with myopia or astigmatic myopia (8 females, 3 males) were included. The mean patient age was 36.3 years (median, 37 years; range, 24-48 years), and the mean spherical equivalent was -5.03 diopters (D) (median, -4.63 D; range, -2.38 to -8.38 D).
METHODS: We performed preoperative and intraoperative A-scan ultrasonography during application of suction using the Hansatome microkeratome (Bausch & Lomb Surgical, Munich, Germany) to create corneal flaps during LASIK. We also performed preoperative and postoperative B-scan ultrasonography of the posterior ocular segment with special attention to the presence and size of posterior vitreous detachment (PVD). MAIN OUTCOME MEASURES: We measured changes in the axial length, anterior chamber depth, lens thickness, and vitreous distance (distance from the posterior lens capsule to the posterior pole) during application of the microkeratome suction ring and recorded new occurrences of or increases in the size of the PVD after surgery.
RESULTS: The lens thickness decreased (mean change, -0.20 mm; P = 0.001; 95% confidence interval [CI], -0.11 to -0.30) in 18 eyes during application of the suction ring. The vitreous distance increased (mean change, 0.20 mm; P = 0.004; 95% CI, 0.08-0.32) in 16 eyes. No statistically significant changes were found in the anterior chamber depth (P = 0.75) or axial length (P = 0.51). After surgery, 3 of 14 eyes (21.4%) experienced PVD that did not have echographic signs of PVD before surgery. Of 7 eyes with preoperative PVD, the PVD enlarged in 1 eye (14.3%).
CONCLUSIONS: During application of microkeratome suction, the lens thickness decreases, whereas the vitreous distance increases, suggesting anterior traction on the posterior segment. The relationship between the observed PVD and LASIK merits further investigation.

Entities:  

Mesh:

Year:  2005        PMID: 15808256     DOI: 10.1016/j.ophtha.2004.11.046

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  8 in total

1.  Retinal colour duplex scanning during LASIK-ring suction with different keratomes.

Authors:  S H Schicke; J Krumeich; G I W Duncker; S Scheibel; M Thielscher
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-05-07       Impact factor: 3.117

2.  [Scanning electron microscopic investigations of cutting edge quality in lamellar keratotomy using the Wavelight femtosecond laser (FS-200) : What influence do spot distance and an additional tunnel have?]

Authors:  T Hammer; T Höche; J Heichel
Journal:  Ophthalmologe       Date:  2018-01       Impact factor: 1.059

3.  Incidence of posterior vitreous detachment after laser in situ keratomileusis.

Authors:  Alireza Mirshahi; Dörte Schöpfer; Daniel Gerhardt; Evdoxia Terzi; Thomas Kasper; Thomas Kohnen
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-07-26       Impact factor: 3.117

4.  Comparison of choroidal thickness in high myopic eyes after FS-LASIK versus implantable collamer lens implantation with swept-source optical coherence tomography.

Authors:  Jing Zhang; Fang-Lin He; Yan Liu; Xian-Qun Fan
Journal:  Int J Ophthalmol       Date:  2020-05-18       Impact factor: 1.779

5.  Retinal measurements using time domain OCT imaging before and after myopic Lasik.

Authors:  Lei Feng; Feng Lei; Stephen A Burns; Liqin Shao; Yabo Yang
Journal:  Ophthalmic Physiol Opt       Date:  2012-05       Impact factor: 3.117

6.  Measurement of the Intraocular Pressure Elevation During Laser-Assisted In Situ Keratomileusis Flap Creation Using a Femtosecond Laser Platform.

Authors:  Gorka Lauzirika; Montserrat Garcia-Gonzalez; Gema Bolivar; José Luis Hernández-Verdejo; Vanesa Blázquez Sánchez; Juan Gros-Otero; Miguel A Teus
Journal:  Transl Vis Sci Technol       Date:  2021-03-01       Impact factor: 3.283

Review 7.  Femtosecond-Laser Assisted Surgery of the Eye: Overview and Impact of the Low-Energy Concept.

Authors:  Catharina Latz; Thomas Asshauer; Christian Rathjen; Alireza Mirshahi
Journal:  Micromachines (Basel)       Date:  2021-01-24       Impact factor: 2.891

8.  Distinct macular thickness changes after femtosecond laser-assisted cataract surgery of age-related cataract and myopia with cataract.

Authors:  Yong Wang; Jun Du; Mei Yang; Yi Xu; Huaijin Guan; Jian Wu
Journal:  Sci Rep       Date:  2018-02-19       Impact factor: 4.379

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.