Literature DB >> 15807822

Assessing the accuracy of Orbscan II post-LASIK: apparent keratectasia is paradoxically associated with anterior chamber depth reduction in successful procedures.

Gerard Cairns1, Susan E Ormonde, Trevor Gray, O Bruce Hadden, Tony Morris, Peter Ring, Charles N J McGhee.   

Abstract

PURPOSE: To establish a relationship between the forward protrusion of the cornea (keratectasia), following successful LASIK, and anterior chamber depth.
METHODS: One hundred and fifteen eyes of 59 patients who had undergone Zyoptix LASIK and 39 eyes of 21 patients who had undergone PlanoScan LASIK at the Eye Institute, Centre for Refractive Surgery, Remuera, Auckland, New Zealand, were included in the study. The results of Orbscan II acquisitions, taken before and 8.3 weeks +/- 4.0 (mean +/- standard deviation) following the procedure, were analysed to determine the amount of forward protrusion of the central 2 mm diameter of the posterior surface. The apparent keratectasia was then related to the Orbscan II anterior chamber depth (ACD) measurement in a linear mixed model analysis that included 'right or left eye', 'sex', 'type of LASIK procedure', 'change in pachymetry', 'postoperative pachymetry', 'change in anterior corneal curvature', 'postoperative anterior corneal curvature', 'planned ablation depth' and 'time until follow-up' as factors and covariates.
RESULTS: The mean +/- SD amount of keratectasia determined by Orbscan II was 22.8 +/- 26.8 microm for the Zyoptix group and 16.9 +/- 24.6 microm for the PlanoScan group. The reduction in depth of the anterior chamber was 14.7 +/- 79.3 microm for the Zyoptix group and 18.2 +/- 68.8 microm for the PlanoScan group. The mixed model analysis demonstrated strong relationships with postoperative pachymetry and change in anterior corneal curvature (P < 0.001 and P < 0.001, respectively). Furthermore, the statistical model showed a marked significant difference in the Orbscan II assessment of keratectasia and change in ACD (P < 0.001).
CONCLUSION: Using the Orbscan II device, the forward protrusion of the posterior corneal surface appears to coincide with a paradoxical reduction in depth of the anterior chamber. Although the keratectasia found in this study is accompanied by thin postoperative corneas and larger central pachymetry change, the contradictory decrease in anterior chamber depth creates uncertainty of measurement, and of ectasia as a mechanism of regression.

Entities:  

Mesh:

Year:  2005        PMID: 15807822     DOI: 10.1111/j.1442-9071.2005.00975.x

Source DB:  PubMed          Journal:  Clin Exp Ophthalmol        ISSN: 1442-6404            Impact factor:   4.207


  9 in total

1.  Analysis of changes in crystalline lens thickness and its refractive power after laser in situ keratomileusis.

Authors:  Liang Wang; Hai-Ke Guo; Jing Zeng; Hai-Ying Jin
Journal:  Int J Ophthalmol       Date:  2012-02-18       Impact factor: 1.779

2.  Changes in Schlemm's canal, trabecular meshwork, and relevant parameters in the early stage after SMILE of myopia patients.

Authors:  Dan-Dan Yang; Zhi-Qi Chen; Wei Chen; He Yin; Jing-Kai Peng; Jun-Ming Wang
Journal:  Int J Ophthalmol       Date:  2022-02-18       Impact factor: 1.779

3.  Personalized pseudophakic model for refractive assessment.

Authors:  Filomena J Ribeiro; António Castanheira-Dinis; João M Dias
Journal:  PLoS One       Date:  2012-10-03       Impact factor: 3.240

4.  Posterior corneal curvature assessment after Epi-LASIK for myopia: comparison of Orbscan II and Pentacam imaging.

Authors:  Yong-Soo Byun; So-Hyang Chung; Young-Geun Park; Choun-Ki Joo
Journal:  Korean J Ophthalmol       Date:  2012-01-14

5.  Two-year observation of posterior corneal elevations after small incision lenticule extraction (SMILE) for myopia higher than -10 dioptres.

Authors:  Xueyi Zhou; Jianmin Shang; Bing Qin; Yu Zhao; Xingtao Zhou
Journal:  Br J Ophthalmol       Date:  2019-04-29       Impact factor: 4.638

6.  Repeatability of corneal parameters with Pentacam after laser in situ keratomileusis.

Authors:  Rajeev Jain; Grewal Dilraj; Satinder Pal Singh Grewal
Journal:  Indian J Ophthalmol       Date:  2007 Sep-Oct       Impact factor: 1.848

7.  A novel color-LED corneal topographer to assess astigmatism in pseudophakic eyes.

Authors:  Tiago B Ferreira; Filomena J Ribeiro
Journal:  Clin Ophthalmol       Date:  2016-08-13

8.  Anterior Chamber Angle and Volume Do Not Change after Myopic Laser-Assisted In Situ Keratomileusis in Young Patients.

Authors:  Ertuğrul Tan Yassa; Cihan Ünlü
Journal:  J Ophthalmol       Date:  2018-12-10       Impact factor: 1.909

9.  Comparison of anterior segment changes after femtosecond laser LASIK and SMILE using a dual rotating Scheimpflug analyzer.

Authors:  Bu Ki Kim; Su Joung Mun; Young Hoon Yang; Ji Sun Kim; Jun Hyung Moon; Young Taek Chung
Journal:  BMC Ophthalmol       Date:  2019-12-11       Impact factor: 2.209

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.