Literature DB >> 15804160

Rat cardiopulmonary bypass model: application of a miniature extracorporeal circuit composed of asanguinous prime.

Xiao-Mang You1, Fadi Nasrallah, Edward Darling, Mike Robins, Gary Nieman, Bruce Searles.   

Abstract

A clinically relevant rat cardiopulmonary bypass (CPB) model would be a valuable tool for investigating pathophysiological and therapeutic strategies on bypass. Previous rat CPB models have been described in the literature; however, they have many limitations, including large circuit surface area, the inability to achieve full bypass, and donor blood requirements for prime. Therefore, we have established a rat CPB model designed to overcome these limitations. The miniature circuit consisted of a filtered reservoir, heat exchanger, membrane oxygenator (surface area = 0.02 m2) with a static priming volume of 2.8 mL, and an inline blood gas monitor. The circuit was primed with 9.5+/-0.5 mL of crystalloid solution and CPB was established on male Sprague-Dawley rats (430-475 g, n = 5) by cannulating the left common carotid artery and the right external jugular vein. The animals were placed on CPB at full flow (111+/-13 mL/kg/ min) for 1 hour and were monitored for and additional 2 hours after the CPB procedure. Hemodynamics, hemoglobin concentration (Hb), and blood gases were analyzed at three time intervals: before, during, and after CPB. The circuit performance was evaluated according to prime volume, compliance, hemodynamic parameters, and gas and heat exchange as described by modified AMMI standards. Data are expressed as mean+/-SD and a repeated-measures analysis of variance with post-Hoc test was used for data comparison between the three time intervals. The ratio of oxygenator surface area to subject body weight for this model is comparable with that of current human adult CPB practice (0.05 m2/kg vs 0.057 m2/kg) Full CPB was achieved and we observed clinically acceptable PaO2, PaCO2, and SvO2 values (209+/-86 mmHg, 25+/-2 mmHg, 78+/-8%, respectively) while on CPB. The use of asanguinous prime did produce statistically significant Hg reduction (15.7+/-0.76 vs. 9.2+/-0.59 g/dL) comparable with clinical practice. No statistically significant differences between pre- and post-CPB hemodynamics and blood gases were found in our study. We have established a miniature circuit consisting of asanquineous prime for a rat CPB model that maintains clinically acceptable results regarding hemodynamic parameters, blood gases, and hemodilution. This model would be valuable for further use in clinically relevant research studies.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15804160      PMCID: PMC4680804     

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  11 in total

Review 1.  A literature review of cardiopulmonary bypass models for rats.

Authors:  P K Ballaux; T Gourlay; C P Ratnatunga; K M Taylor
Journal:  Perfusion       Date:  1999-11       Impact factor: 1.972

2.  Early experience with a new technique and technology designed for the study of pulsatile cardiopulmonary bypass in the rat.

Authors:  Terence Gourlay; Philippe K Ballaux; Edward R C Draper; Kenneth M Taylor
Journal:  Perfusion       Date:  2002-05       Impact factor: 1.972

3.  Cerebral embolisation during modern cardiopulmonary bypass.

Authors:  S J Fearn; R Pole; M Burgess; S G Ray; T L Hooper; C N McCollum
Journal:  Eur J Cardiothorac Surg       Date:  2001-12       Impact factor: 4.191

4.  Effect of extracorporeal circulation on reticuloendothelial function. I. Experimental evidence for impaired reticuloendothelial function following cardiopulmonary bypass in rats.

Authors:  V Subramanian; J McLeod; H Gans
Journal:  Surgery       Date:  1968-10       Impact factor: 3.982

5.  Hypothermic cardiopulmonary bypass in white rats.

Authors:  P Popovic; J Horecky; V P Popovic
Journal:  Ann Surg       Date:  1968-08       Impact factor: 12.969

6.  An oxygenator for cardiopulmonary bypass in the rat.

Authors:  E Proctor
Journal:  J Surg Res       Date:  1977-02       Impact factor: 2.192

7.  Prolonged partial cardiopulmonary bypass in rats.

Authors:  B Alexander; H R Al Ani
Journal:  J Surg Res       Date:  1983-07       Impact factor: 2.192

8.  Neurological injury during cardiopulmonary bypass in the rat.

Authors:  H P Grocott; G B Mackensen; M F Newman; D S Warner
Journal:  Perfusion       Date:  2001-01       Impact factor: 1.972

9.  Partial cardiopulmonary bypass in rats for evaluating ischemia-reperfusion injury.

Authors:  S Sasaki; K Takigami; N Shiiya; K Yasuda
Journal:  ASAIO J       Date:  1996 Nov-Dec       Impact factor: 2.872

10.  Phosphodiesterase type 4 inhibitor prevents acute lung injury induced by cardiopulmonary bypass in a rat model.

Authors:  Masaki Hamamoto; Michiharu Suga; Takeshi Nakatani; Yuzo Takahashi; Yukio Sato; Shuji Inamori; Toshikatsu Yagihara; Soichiro Kitamura
Journal:  Eur J Cardiothorac Surg       Date:  2004-05       Impact factor: 4.191

View more
  6 in total

1.  Inhaled carbon monoxide attenuates myocardial inflammatory cytokine expression in a rat model of cardiopulmonary bypass.

Authors:  Juan N Pulido; James R Neal; Carlos B Mantilla; Shvetank Agarwal; Won-Yeon Lee; Phillip D Scott; Rolf D Hubmayr; Wen-Zhi Zhan; Gary C Sieck; Gianrico Farrugia; Mark H Ereth
Journal:  J Extra Corpor Technol       Date:  2011-09

2.  Impairment of diaphragm muscle force and neuromuscular transmission after normothermic cardiopulmonary bypass: effect of low-dose inhaled CO.

Authors:  Leonid G Ermilov; Juan N Pulido; Fawn W Atchison; Wen-Zhi Zhan; Mark H Ereth; Gary C Sieck; Carlos B Mantilla
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2010-01-20       Impact factor: 3.619

Review 3.  ESC working group cellular biology of the heart: position paper: improving the preclinical assessment of novel cardioprotective therapies.

Authors:  Sandrine Lecour; Hans E Bøtker; Gianluigi Condorelli; Sean M Davidson; David Garcia-Dorado; Felix B Engel; Peter Ferdinandy; Gerd Heusch; Rosalinda Madonna; Michel Ovize; Marisol Ruiz-Meana; Rainer Schulz; Joost P G Sluijter; Linda W Van Laake; Derek M Yellon; Derek J Hausenloy
Journal:  Cardiovasc Res       Date:  2014-10-24       Impact factor: 10.787

4.  Establishment and evaluation of a rat model of extracorporeal membrane oxygenation (ECMO) thrombosis using a 3D-printed mock-oxygenator.

Authors:  Nao Umei; Angela Lai; Jennifer Miller; Suji Shin; Kalliope Roberts; Saif Ai Qatarneh; Shingo Ichiba; Atsuhiro Sakamoto; Keith E Cook
Journal:  J Transl Med       Date:  2021-04-28       Impact factor: 5.531

5.  Intravital microscopic observation of the microvasculature during hemodialysis in healthy rats.

Authors:  B G H Janssen; Y M Zhang; I Kosik; A Akbari; C W McIntyre
Journal:  Sci Rep       Date:  2022-01-07       Impact factor: 4.379

6.  Application of alpha1-antitrypsin in a rat model of veno-arterial extracorporeal membrane oxygenation.

Authors:  Fabian Edinger; Christoph Schmitt; Christian Koch; J Michael McIntosh; Sabina Janciauskiene; Melanie Markmann; Michael Sander; Winfried Padberg; Veronika Grau
Journal:  Sci Rep       Date:  2021-08-04       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.