Simultaneous determination of amantadine and rimantadine by HPLC in rat plasma with pre-column derivatization and fluorescence detection for pharmacokinetic studies.

Yasuhiko Higashi1, Izumi Uemori, Youichi Fujii.   

Abstract

We investigated simultaneous high-performance liquid chromatographic (HPLC) determination of amantadine hydrochloride (AMA) and rimantadine hydrochloride (RIM) levels in rat plasma after fluorescent derivatization with o-phthalaldehyde and 2-mercaptoethanol. Afterwards, the method was applied to determine their pharmacokinetics. The retention times of AMA and RIM derivatives were 12.6 and 22.2 min and the lower limits of detection were 0.025 and 0.016 microg/mL, respectively. The coefficients of variation for intra- and inter-day assay of AMA and RIM were less than 5.1 and 7.6%, respectively. After i.v. administration of AMA or RIM to rats, the total body clearance and distribution volume at the steady-state of RIM were higher than those of AMA. Bioavailability of AMA and RIM was 34.9 and 37.2%, respectively. When AMA and RIM were p.o. co-administered, the area under the plasma concentration--time curve of RIM was significantly lower than that after RIM alone. On the other hand, pharmacokinetic parameters of AMA did not significantly change. These results indicate that our HPLC assay is simple, rapid, sensitive and reproducible for simultaneously determining AMA and RIM concentrations in rat plasma and is applicable to their pharmacokinetic studies. Also, co-administration of AMA and RIM may result in the lack of pharmacological effects of RIM.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15803448     DOI: 10.1002/bmc.492

Source DB:  PubMed          Journal:  Biomed Chromatogr        ISSN: 0269-3879            Impact factor:   1.902


  2 in total

1.  Quantitative trace analysis of a broad range of antiviral drugs in poultry muscle using column-switch liquid chromatography coupled to tandem mass spectrometry.

Authors:  Bjorn J A Berendsen; Robin S Wegh; Martien L Essers; Alida A M Stolker; Stefan Weigel
Journal:  Anal Bioanal Chem       Date:  2011-12-16       Impact factor: 4.142

2.  Sensitive and rapid determination of amantadine without derivatization in human plasma by LC-MS/MS for a bioequivalence study.

Authors:  Abhaysingh Bhadoriya; Shivprakash Rathnam; Bhavesh Dasandi; Dharmesh Parmar; Mallika Sanyal; Pranav S Shrivastav
Journal:  J Pharm Anal       Date:  2018-02-21
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.