Literature DB >> 15799803

Using Dermabond for wound closure in lumbar and cervical neurosurgical procedures.

Lance T Hall1, Julian E Bailes.   

Abstract

OBJECTIVE: 2-Octylcyanoacrylate (Dermabond; Ethicon, Inc., Somerville, NJ) is a liquid adhesive being used with increasing frequency for the closure of lacerations and surgical incisions. Dermabond provides excellent cosmetic closure, and recent studies have demonstrated very low infection risks when it is properly applied. There are no published studies using Dermabond on lumbar or cervical procedures. This study was undertaken to determine whether Dermabond is safe and efficacious to use in these common neurosurgical procedures.
METHODS: Records of 200 consecutive patients with Dermabond closure after anterior cervical discectomy, microlumbar discectomy, or lumbar laminectomy by the senior author (JEB) with a mean follow-up time of 5.42 months were retrospectively reviewed. Suspected infections with or without confirmatory cultures, erythema, and incisional drainage were documented.
RESULTS: Of 200 patients, 85 underwent microlumbar discectomy, 22 lumbar laminectomy, and 93 anterior cervical discectomy. There was only 1 definitive infection, which was a culture-proven discitis in a microlumbar discectomy patient. Of the remaining 85 microlumbar discectomies, there was 1 transient incisional erythema. Of the 22 lumbar laminectomies, there was 1 patient with clinical superficial wound infection with negative cultures and 4 patients with transient incisional drainage without infection. Of the 93 anterior cervical discectomies, 2 had transient incisional drainage without infection.
CONCLUSION: This study demonstrates that Dermabond is safe to use in neurosurgery patients undergoing lumbar or cervical procedures, with only 1 patient of 200 having a proven infection. Patients are able to shower and do not have sutures or staples to remove. Patient responses are overwhelmingly positive.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15799803     DOI: 10.1227/01.neu.0000144170.39436.52

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  6 in total

1.  Surgical site infection in spinal surgery: a comparative study between 2-octyl-cyanoacrylate and staples for wound closure.

Authors:  Muneharu Ando; Tetsuya Tamaki; Munehito Yoshida; Shunji Sasaki; Yasushi Toge; Takuji Matsumoto; Kazuhiro Maio; Ryosuke Sakata; Daisuke Fukui; Seiji Kanno; Yukihiro Nakagawa; Hiroshi Yamada
Journal:  Eur Spine J       Date:  2014-02-01       Impact factor: 3.134

2.  2-Octyl-cyanoacrylate for wound closure in cervical and lumbar spinal surgery.

Authors:  Dorothee Wachter; Anja Brückel; Marco Stein; Matthias F Oertel; Petros Christophis; Dieter-Karsten Böker
Journal:  Neurosurg Rev       Date:  2010-05-04       Impact factor: 3.042

3.  Rash with DERMABOND PRINEO Skin Closure System Use in Bilateral Reduction Mammoplasty: A Case Series.

Authors:  R W Knackstedt; J A Dixon; P J O'Neill; F A Herrera
Journal:  Case Rep Med       Date:  2015-04-01

Review 4.  Cyanoacrylate Dermal Closure in Spine Surgery: Systematic Review and Pooled Analysis.

Authors:  Terence Tan; Joost Rutges; Travis Marion; Martin Hunn; Jin Tee
Journal:  Global Spine J       Date:  2019-07-10

5.  Optimization of tissue adhesive curing time for surgical wound closure.

Authors:  Ian J Wellington; Benjamin C Hawthorne; Caitlin Dorsey; John P Connors; Augustus D Mazzocca; Olga Solovyova
Journal:  Bone Jt Open       Date:  2022-08

6.  A prospective randomized comparison of two skin closure techniques in acetabular fracture surgery.

Authors:  Christopher D Mudd; John A Boudreau; Berton R Moed
Journal:  J Orthop Traumatol       Date:  2013-12-31
  6 in total