Literature DB >> 15799051

Open half-volume quadrature transverse electromagnetic coil for high-field magnetic resonance imaging.

A S Peshkovsky1, R P Kennan, M E Fabry, N I Avdievich.   

Abstract

A half-volume quadrature head transverse electromagnetic (TEM) coil has been constructed for 4 T imaging applications. This coil produces a sufficiently large homogeneous B(1) field region for the use as a volume coil. It provides superior transmission efficiency, resulting in significantly lower power deposition, as well as greater sensitivity and improved patient comfort and accessibility compared with conventional full-volume coils. Additionally, this coil suppresses the RF penetration artifact that distorts the RF magnetic field profile and alters the intensity in high-field images recorded with linear surface and volume coils. These advantages make it possible to apply this device as an efficient transmit/receive coil for high-field imaging with a restricted field of view. Copyright 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2005        PMID: 15799051     DOI: 10.1002/mrm.20422

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

1.  1 H-13 C independently tuned radiofrequency surface coil applied for in vivo hyperpolarized MRI.

Authors:  Peng Cao; Xiaoliang Zhang; Ilwoo Park; Chloe Najac; Sarah J Nelson; Sabrina Ronen; Peder E Z Larson
Journal:  Magn Reson Med       Date:  2015-11-24       Impact factor: 4.668

2.  Optimization of a transmit/receive surface coil for squirrel monkey spinal cord imaging.

Authors:  Ming Lu; Feng Wang; Li Min Chen; John C Gore; Xinqiang Yan
Journal:  Magn Reson Imaging       Date:  2020-02-19       Impact factor: 2.546

3.  Maximizing sensitivity for fast GABA edited spectroscopy in the visual cortex at 7 T.

Authors:  Arjan D Hendriks; Alessio Fracasso; Catalina S Arteaga de Castro; Mark W J M Gosselink; Peter R Luijten; Natalia Petridou; Dennis W J Klomp
Journal:  NMR Biomed       Date:  2018-02-14       Impact factor: 4.044

4.  Planar quadrature RF transceiver design using common-mode differential-mode (CMDM) transmission line method for 7T MR imaging.

Authors:  Ye Li; Baiying Yu; Yong Pang; Daniel B Vigneron; Xiaoliang Zhang
Journal:  PLoS One       Date:  2013-11-12       Impact factor: 3.240

5.  A Novel Metamaterial-Inspired RF-coil for Preclinical Dual-Nuclei MRI.

Authors:  Anna Hurshkainen; Anton Nikulin; Elodie Georget; Benoit Larrat; Djamel Berrahou; Ana Luisa Neves; Pierre Sabouroux; Stefan Enoch; Irina Melchakova; Pavel Belov; Stanislav Glybovski; Redha Abdeddaim
Journal:  Sci Rep       Date:  2018-06-15       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.