Literature DB >> 15798683

In vitro fracture resistance of endodontically treated central incisors with varying ferrule heights and configurations.

Philip L B Tan1, Steven A Aquilino, David G Gratton, Clark M Stanford, Swee Chian Tan, William T Johnson, Deborah Dawson.   

Abstract

STATEMENT OF PROBLEM: The in vitro effectiveness of a uniform circumferential ferrule has been established in the literature; however, the effect of a nonuniform circumferential ferrule height on fracture resistance is unknown.
PURPOSE: This in vitro study investigated the resistance to static loading of endodontically treated teeth with uniform and nonuniform ferrule configurations.
MATERIAL AND METHODS: Fifty extracted intact maxillary human central incisors were randomly assigned to 1 of 5 groups: CRN, no root canal treatment (RCT), restored with a crown; RCT/CRN, no dowel/core, restored with a crown; 2 FRL, 2-mm ferrule, cast dowel/core and crown; 0.5/2 FRL, nonuniform ferrule (2 mm buccal and lingual, 0.5 mm proximal), cast dowel/core and crown; and 0 FRL, no ferrule, cast dowel/core and crown. The teeth were prepared to standardized specifications and stored for 72 hours in 100% humidity prior to testing. Testing was conducted with a universal testing machine with the application of a static load, and the load (N) at failure was recorded. Statistical analysis was performed with a 1-way analysis of variance and the Tukey Honestly Significant Difference test (alpha=.05). The mode of fracture was noted by visual inspection for all specimens.
RESULTS: There was strong evidence of group differences in mean fracture strength ( P <.0001). Following adjustment for all pairwise group comparisons, it was found that the lack of a ferrule resulted in a significantly lower mean fracture strength (0 FRL: 264.93 +/- 78.33 N) relative to all other groups. The presence of a nonuniform (0.5 to 2-mm vertical height) ferrule (0.5/2 FRL: 426.64 +/- 88.33 N) resulted in a significant decrease ( P =.0001) in mean fracture strength when compared with the uniform 2-mm vertical ferrule (2 FRL: 587.23 +/- 110.25 N), the group without RCT (CRN: 583.67 +/- 86.09 N), and the RCT-treated tooth with a crown alone (CRN/RCT: 571.04 +/- 154.86 N). The predominant mode of failure was an oblique fracture extending from the lingual margin to the facial surface just below the insertion of the tooth into the acrylic resin.
CONCLUSION: The results demonstrated that central incisors restored with cast dowel/core and crowns with a 2-mm uniform ferrule were more fracture resistant compared to central incisors with nonuniform (0.5 to 2 mm) ferrule heights. Both the 2-mm ferrule and nonuniform ferrule groups were more fracture resistant than the group that lacked a ferrule.

Entities:  

Mesh:

Year:  2005        PMID: 15798683     DOI: 10.1016/j.prosdent.2005.01.013

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  26 in total

1.  Periodontal response to two different subgingival restorative margin designs: a 12-month randomized clinical trial.

Authors:  Gianluca Paniz; Jose Nart; Luca Gobbato; Andrea Chierico; Diego Lops; Konstantinos Michalakis
Journal:  Clin Oral Investig       Date:  2015-10-08       Impact factor: 3.573

2.  Effect of Different Ferrule Length on Fracture Resistance of Endodontically Treated Teeth: An In vitro Study.

Authors:  Sushil Kar; Arvind Tripathi; Chavi Trivedi
Journal:  J Clin Diagn Res       Date:  2017-04-01

3.  Four-year Survival of Endodontically Treated Premolars Restored with Fiber Posts.

Authors:  J Juloski; G M Fadda; F Monticelli; M Fajó-Pascual; C Goracci; M Ferrari
Journal:  J Dent Res       Date:  2014-03-19       Impact factor: 6.116

4.  Minimally invasive endodontics: challenging prevailing paradigms.

Authors:  A H Gluskin; C I Peters; O A Peters
Journal:  Br Dent J       Date:  2014-03       Impact factor: 1.626

5.  Adhesive restoration of anterior endodontically treated teeth: influence of post length on fracture strength.

Authors:  Anaïs Ramírez-Sebastià; Tissiana Bortolotto; Maria Cattani-Lorente; Lluis Giner; Miguel Roig; Ivo Krejci
Journal:  Clin Oral Investig       Date:  2013-04-20       Impact factor: 3.573

6.  Fracture load of tooth restored with fiber post and experimental short fiber composite.

Authors:  Jasmina Bijelic; Sufyan Garoushi; Pekka K Vallittu; Lippo V J Lassila
Journal:  Open Dent J       Date:  2011-03-29

7.  Evaluation of the effect of different ferrule designs on fracture resistance of maxillary incisors restored with bonded posts and cores.

Authors:  Z Mahdavi Izadi; E Jalalian; A Eyvaz Ziaee; L Zamani; B Javanshir
Journal:  J Dent (Tehran)       Date:  2010-09-30

8.  An assessment of fracture resistance of three composite resin core build-up materials on three prefabricated non-metallic posts, cemented in endodontically treated teeth: an in vitro study.

Authors:  Lalit Kumar; Bhupinder Pal; Prashant Pujari
Journal:  PeerJ       Date:  2015-02-24       Impact factor: 2.984

9.  A survey of failed post-retained restorations.

Authors:  A Peutzfeldt; A Sahafi; E Asmussen
Journal:  Clin Oral Investig       Date:  2007-07-17       Impact factor: 3.573

10.  Fracture Resistance of Teeth Restored with Various Post Designs and Cemented with Different Cements: An In-vitro Study.

Authors:  Ajay Gaikwad; Kapil Singh Pal; L M Ranganath; Jayesh Kumar Jain; Prashanth Patil; Geetika Babar
Journal:  J Int Oral Health       Date:  2015
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.